Perlick HP15BS34R Manual Do Proprietário

Página de 12
PERLICK RESIDENTIAL INSTALLATION MANUAL
6
perlick.com
Signature Series – HP15 Models
Model
Min Temp Set
Max Temp Set
HP15R
33° F
42° F
HP15B
33° F
48° F
HP15W
45° F
65° F
HP15T
33° F
42° F
Signature Series – HP24 Models
Model
Min Temp Set
Max Temp Set
HP24R
33° F
42° F
HP24F
-10° F
10° F
HP24B
33° F
48° F
HP24W
45° F
65° F
HP24T
33° F
42° F
Signature Series – HP48 Models
Model
Min Temp Set
Max Temp Set
HP48WO
40° F
65° F
HP48WW
40° F
65° F
Signature Series Sottile
Model
Min Temp Set
Max Temp Set
HH24RS
33°
42°
HH24BS
33°
48°
HH24WS
45°
65°
C-Series Models
Model
Min Temp Set
Max Temp Set
HC24R
33° F
42° F
HC24BB
33° F
48° F
HC24WB
45° F
65° F
ADA-Compliant Series
Model
Min Temp Set
Max Temp Set
HA24FB
-10°
10
LED Functions
The following table describes LED functions
LED
Mode
Function
ON
Compressor is on
Flashing
Anti-short cycle
delay is on
ON
Defrost is on
ON
Alarm is on
Flashing
You are in the process of 
programming the unit
DIAL TEMPERATURE CONTROL
ADA-Compliant Models
(Excludes ADA Freezer - HA24F models use digital controller 
found on page 5)
 
C
O
O
LE
R
OFF
1
2
3
4
5
6
COLD
Figure 2.  Dial Temperature Controller
Use a straight slot screwdriver to adjust the dial 
temperature control. The control is located at the top rear 
panel of the cabinet. Approximate temperature ranges are 
as follows:
ADA-Compliant Series
Model
Temp Range
HA24RB
33° - 42° F
HA24BB
35° - 48° F
HA24WB
45° - 65° F
 
Adjust the temperature as follows:
Colder Temperature:
Turn the adjusting screw clockwise (to the right).
Warmer Temperature:
Turn the adjusting screw counterclockwise (to the left).
Temperature Control OFF:
Turn the adjusting screw completely counterclockwise to 
the OFF position until a click is heard.
NOTE: The condenser fan motor turns off with the compressor.