Best MD6T Guia Da Instalação

Página de 12
MODELS  MD6T • MD8T
Page 3
Damper and outside air duct connected directly to a ceiling, floor, or wall register.
INTERIOR WALL
WALL
REGISTER
REGISTER BOX ADAPTED
WITH SLIDE-IN FILTER (optional)
MOTORIZED DAMPER
FIELD MEASUREMENT OF OUTSIDE
AIR DUCT PRESSURE. (See “Install The
Damper” section on page 3 for damper
balancing instructions.)
WALL CAP WITH
BIRD SCREEN
INSULATED OUTSIDE
AIR DUCT (slope toward wall cap)
EXTERIOR WALL
VENTILATION AIR INTAKE
(locate away from pollutant sources)
INSTALL THE DAMPER
Once  the  Damper  and  the  associated  Broan  or  BEST  exhaust
devices are installed, the installer should confirm that the Damper
opens  and  closes  in  conjunction  with  signals  from  the  exhaust
devices(s) as intended.
A  qualified  HVAC  contractor  should  also  ensure  the  proper
operation and venting of all combustion equipment in the home.
SYSTEM OPERATION
Regular maintenance is necessary to ensure the proper operation
of the Damper system. Failure to conduct such routine maintenance
can jeopardize the ability of the Damper to introduce fresh air into the
home. Regular maintenance should include the following activities:
•  Clean the outside bird screen to ensure it is free from debris and
open to allow fresh air to enter.
•  Clean or replace the interior filter(s) which serve to filter fresh air
before it enters the home.
•  Maintain a clear opening at the outdoor end cap, which means
preventing the buildup of snow, leaves, or vegetation at the end
cap.
•  During regular HVAC maintenance, have the mechanical contrac-
tor inspect the Damper system for proper operation.
MAINTENANCE
OUTSIDE AIR
TO CENTRAL SYSTEM
RETURN AIR OR INTERIOR
WALL REGISTER 
DAMPER FLAP (Install in
vertical position shown.)
AIR FLOW
AIR FLOW
SET SCREW
WHT
WHT
120 VAC
60 HZ
BLK
BLK
BLK
WHT
ORG
24V
WHT
BLK
MAKE-UP AIR
DAMPER
24V
TRANSFORMER
(included)
HOOD
GRD
MODEL E60000 SERIES & E64000 SERIES
MAKE-UP AIR DAMPER CONNECTION
         (switched high voltage)
Install the damper as shown. Make sure damper flap is in a vertical
position when closed and power is off. The set screw can be used
to adjust the damper opening - thereby balancing the inside and
outside air pressure when the range hood exhausts at high speed.
Wire the system as shown.
20 GAUGE BELL WIRE TO
HOOD
CONTACT CONNECTIONS ON
BACK OF HOOD
MODEL QP3 SERIES
MAKE UP DAMPER CONNECTION
        (switched low voltage)
MAKE-UP AIR
DAMPER
GRD
120 VAC
60 HZ
24V
TRANSFORMER
(included)