Friedrich SH20M50A Ficha De Dados
Front
SIDE VIEW
(A)
Junction
Box
Box
Max.
Wall
Depth
LISTED
ROOM AIR CONDITIONERS
183H
Sleeve Dimensions Drawing
Due to continuing engineering research and technology, specifications are subject to change without notice. Manufactured under U.S. Design Patent
DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. MAXIMUM TEMPERATURE
RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. MAXIMUM TEMPERATURE
RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
Installation Information
Hazardgard_Submital_2013
Specifications
Model
Cooling Capacity
Electrical Characteristics
Energy
Efficiency
Ratio
Moisture
Removal
Air Direction
Controls
Air Circulation
Refrigerant
Cooling
Cooling
Btu
Volts Rated
Amps
Watts
EER
Pints/ HR
CFM
6 0 H E r T z - n o r T H a M E r I C a
SH15M30a
14500/14000
230/208
6.9/7.5
1495/1443
9.7/9.7
6.0
8-way
375
r-410a
SH20M30a
20000/19000
230/208
8.7/9.6
2125/2021
9.4/9.4
4.0
8-way
375
r-410a
5 0 H E r T z - I n T E r n a T I o n a L
SH20M50a
19500/19100
240/220
9.8/10.3
2167/2156
9.0/9.0
5.6/5.5
8-way
425
r-410a
Model
Dimensions
INCHES
Window
Width
INCHES
In-Wall Installation
Finished Hole INCHES
Circuit Rating
Breaker or
T - D Fuse
Weight
Lbs.
Height
Width
Depth with
Front
Depth J Box
to Louvers
Minimum
Extension
Into Room
Into Room
Minimum
Extension
Outside
Min.
Max.
Height
Width Max. Depth
Volts - Amps
Net Shipping
SH15M30a
15
15
/
16”
25
15
/
16”
27
3
/
8”
6
”
3
1
/
16”
16
15
/
16”
27
7
/
8”
42
”
16
3
/
16”
26
3
/
16”
6
”
250v-15
140
167
SH20M30a
17
15
/
16”
25
15
/
16”
27
3
/
8”
6
”
3
1
/
16”
16
15
/
16”
27
7
/
8”
42
”
18
3
/
16”
26
3
/
16”
6
”
250v-15 (230v) 166
170
250v-20 (208v)
SH20M50a
17
15
/
16”
25
15
/
16”
27
3
/
8”
6
”
3
1
/
16”
16
15
/
16”
27
7
/
8”
42
”
18
3
/
16”
26
3
/
16”
6
”
250v-15
171
175
(A)
T4 temperature classification means unit surface temperatures will not
rise above 135° C/275° F. operates at low ambient conditions without
freezing at outdoor ambient temperatures as low as 7° C/45° F.
Tolerates higher outdoor temperatures up to 55° C /130° F.
rise above 135° C/275° F. operates at low ambient conditions without
freezing at outdoor ambient temperatures as low as 7° C/45° F.
Tolerates higher outdoor temperatures up to 55° C /130° F.
Equipment is certified in accordance with ISa 12.12.01 and nFPa 70-10
(national Electric Code)
(national Electric Code)
arTICLE 501
arTICLE 505
Class I, Div. 2, Group a and Group B
Class I, zone 2, Group IIC
Class I, Div. 2, Group B
Class I, zone 2, Group IIB
plus hydrogen, or “+H2”
Class I, Div. 2, Group C
Class I, zone 2, Group IIB
Class I, Div. 2, Group D
Class I, zone 2, Group IIa