ELECTRICAL REQUIREMENTS
IMPORTANT: The range must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate. 
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit
is required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this range be provided. 
Electronic ignition systems operate within wide voltage
limits, but proper grounding and polarity are necessary. 
Check that the outlet provides 120-volt power and is 
correctly grounded.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61.0 cm) base cabinet depth and 36" 
(91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.
Range may be installed next to combustible walls with zero 
clearance.
NOTE: When installed in a slide-in cutout, the front of oven 
door may protrude beyond the base cabinet.
*NOTE: 24" (61.0 cm) minimum when bottom of wood or
metal cabinet is shielded by not less than 
1
4
" (0.64 cm) flame
retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood or
metal cabinet.
A.   18" (45.7 cm) upper side cabinet to countertop
B.   13" (33 cm) max. upper cabinet depth
C.   30" (76.2 cm) min. opening width
D.   For minimum clearance to top of cooktop, see NOTE*.
E.   30" (76.2 cm) min. opening width
F.   3" (7.6 cm) min. clearance from both sides of range to side wall or
     other combustible material.
G.  The shaded area is recommended for installation of rigid gas pipe
     and grounded outlet.
H.   13 
1
8
" (33.3 cm)
I.    7 
11
16
" (19.5 cm)
J.   4 
13
16
"" (12.2 cm)
K.   3 
11
16
" (9.4 cm) or measurement of N, whichever is greater
L.  12" (30.5 cm)
M. Cabinet door or hinges should not extend into the cutout.
N.  Remaining counter depth should not exceed 2¼" (5.7 cm)
Page 2 of 2
Because Whirlpool Corporation policy includes a continuous commitment to 
improve our products, we reserve the right to change materials and specifications 
without notice.
Dimensions are for planning purposes only. For complete details, see 
Installation Instructions packed with product. Specifications subject to 
change without notice.
Ref. W10665256E