Marvel ML24BSP3RP Ficha De Características
17
!
CAUTION
Material Type
#10 Wood Screw
Hardwood
1
⁄
8
" (3.2 mm) Diameter. Pilot Hole
Softwood
7
⁄
64
(2.8 mm) Diameter. Pilot Hole
Table B
Step 5: Install the door
Carefully open the top and bottom hinges on the door being
careful as there are many pinch points. Place the hinges
over the 4 screws in the cabinet, 2 at the top and 2 at the
bottom and slide the door into position. Tighten the 4 hinge
screws with a phillips screwdriver. (See Figures 13 and
13a). Place wire harness from the grille and mount to the
bottom of the door with the screw and "P" clamp removed
in step 1. (See Figure 13b). Reconnect the wire harness,
(See Figure 14).
Step 4: Assemble the panel to the door
The preferred method of attaching the panel to the door
is to clamp the panel to the door so it cannot move while
drilling the screw pilot holes. Use bar clamps or "C" clamps
with pads on the clamping surfaces that will not mar the
panel or the door. The custom overlay panel should be
flush with the top of the door and centered along the width
of the door. See Figure 15a. Drill holes through the gasket
extrusion using the 10 holes as pilot holes. Use the drill
size from the chart in Table "B", being careful not to drill
through the front surface of the panel, drill no deeper than
1
⁄
2
" (12.7 mm) deep. If the overlay panel is thinner than
5
⁄
8
" (16 mm) thick shorter screws will have to be obtained.
Fasten the panel to the door with the 10 screws provided
in the literature pack. (See Figure 20). Remove the clamps
and replace the gasket in the gasket extrusion channels of
the door. Some force may be required to seat the gasket
into the channels. Be sure the gasket corners are seated
properly.
Figure 20
#10 x 1/2"
screw
Weight of overlay door panel must not
exceed 15 pounds (6.8 kg) for a solid
door model.
OVERLAY DOOR PANEL INSTALLATION
17
!
CAUTION
Material Type
#10 Wood Screw
Hardwood
1
⁄
8
" (3.2 mm) Diameter. Pilot Hole
Softwood
7
⁄
64
(2.8 mm) Diameter. Pilot Hole
Table B
Step 5: Install the door
Carefully open the top and bottom hinges on the door being
careful as there are many pinch points. Place the hinges
over the 4 screws in the cabinet, 2 at the top and 2 at the
bottom and slide the door into position. Tighten the 4 hinge
screws with a phillips screwdriver. (See Figures 13 and
13a). Place wire harness from the grille and mount to the
bottom of the door with the screw and "P" clamp removed
in step 1. (See Figure 13b). Reconnect the wire harness,
(See Figure 14).
Step 4: Assemble the panel to the door
The preferred method of attaching the panel to the door
is to clamp the panel to the door so it cannot move while
drilling the screw pilot holes. Use bar clamps or "C" clamps
with pads on the clamping surfaces that will not mar the
panel or the door. The custom overlay panel should be
flush with the top of the door and centered along the width
of the door. See Figure 15a. Drill holes through the gasket
extrusion using the 10 holes as pilot holes. Use the drill
size from the chart in Table "B", being careful not to drill
through the front surface of the panel, drill no deeper than
1
⁄
2
" (12.7 mm) deep. If the overlay panel is thinner than
5
⁄
8
" (16 mm) thick shorter screws will have to be obtained.
Fasten the panel to the door with the 10 screws provided
in the literature pack. (See Figure 20). Remove the clamps
and replace the gasket in the gasket extrusion channels of
the door. Some force may be required to seat the gasket
into the channels. Be sure the gasket corners are seated
properly.
Figure 20
#10 x 1/2"
screw
Weight of overlay door panel must not
exceed 15 pounds (6.8 kg) for a solid
door model.
OVERLAY DOOR PANEL INSTALLATION
Overlay Panels
14
!
CAUTION
1
5
⁄
32
"
(2.9 cm)
Figure 17
Right Hand Hinged Door
24" (61 cm) wide appliance
Figure 18
Right Hand Hinged Door
24" (61 cm) wide appliance
OVERLAY DOOR PANEL INSTALLATION
1" (2.5 cm) diameter
x
1
⁄
4
" (6 mm) deep
4 places
Clearance
for hinge
at top and
bottom
2"
(5.1 cm)
3
11
⁄
16
"
(9.4 cm)
1
1
⁄
2
"
(3.8 cm)
typical
1
⁄
4
"
(6 mm)
Deep
Hinge side of door
Clearance for
screw head,
4 places
30
11
⁄
32
"
(77.1 cm)
1
11
⁄
16
"
(4.3 cm)
23
3
⁄
4
"
(60.3 cm)
3
1
⁄
8
"
(7.9 cm)
Top of door
Step 4: Assemble the panel to the door
The preferred method of attaching the panel to the door
is to clamp the panel to the door so it cannot move while
drilling the screw pilot holes. Use bar clamps or "C" clamps
with pads on the clamping surfaces that will not mar the
panel or the door. The custom overlay panel should be
flush with the top of the door and centered along the width
of the door. See Figure 10a. Drill holes through the gasket
extrusion using the 10 holes as pilot holes. Use the drill
size from the chart in Table "C", being careful not to drill
through the front surface of the panel, drill no deeper than
1
⁄
2
" (12.7 mm) deep. If the overlay panel is thinner than
5
⁄
8
" (16 mm) thick shorter screws will have to be obtained.
Fasten the panel to the door with the 10 screws provided in
the literature pack. (See Figure 19a). Remove the clamps
and replace the gasket in the gasket extrusion channels of
the door. Some force may be required to seat the gasket
into the channels. Be sure the gasket corners are seated
properly.
Material Type
#10 Wood Screw
Hardwood
1
⁄
8
" (3.2 mm) Diameter. Pilot Hole
Softwood
7
⁄
64
(2.8 mm) Diameter. Pilot Hole
Table C
Weight of overlay door panel must not exceed 15
pounds (6.8 kg) for a solid door model or 10 pounds
(4.5 kg) for a glass door model.
3
1
⁄
8
"
(7.9 cm)
1
3
⁄
4
"
(4.4 cm)
4
1
⁄
8
"
(10.5 cm)
1
⁄
4
" (6 mm)
radius is
permissible
This side
to door
3
1
⁄
8
"
(7.9 cm)
3
27
⁄
32
"
(9.8 cm)
1
3
⁄
16
"
(3 cm)
14"
(35.6 cm)
4
7
⁄
8
"
(12.4 cm)
For comprehensive installation instructions,
please visit www.marvelrefrigeration.com
16
1
5
⁄
32
"
(2.9 cm)
1
5
⁄
32
"
(2.9 cm)
OVERLAY DOOR PANEL INSTALLATION
Clearance
for hinge
at top and
bottom
Clearance for hinge
at top and bottom
Clearance for
screw head,
4 places
Top of door
Hinge side of door
Clearance for
screw head,
4 places
Figure 18
Right Hand Hinged Door
24" (61 cm) wide appliance
Figure 16
Left Hand Hinged Door
24" (61 cm) wide appliance
Hinge side of door
Top of door
23
3
⁄
4
"
(60.3 cm)
1
⁄
4
"
(6 mm)
Deep
23
3
⁄
4
"
(60.3 cm)
1
⁄
4
"
(6 mm)
Deep
Figure 17
Left Hand Hinged Door
24" (61 cm) wide appliance
1" (2.5 cm) diameter
x
1
⁄
4
" (6 mm) deep
4 places
1
1
⁄
2
"
(3.8 cm)
typical
1
11
⁄
16
"
(4.3 cm)
2"
(5.1 cm)
3
11
⁄
16
"
(9.4 cm)
Figure 19
Right Hand Hinged Door
24" (61 cm) wide appliance
2"
(5.1 cm)
3
11
⁄
16
"
(9.4 cm)
1
1
⁄
2
"
(3.8 cm)
typical
1
11
⁄
16
"
(4.3 cm)
4
7
⁄
8
"
(12.4 cm)
14"
(35.6 cm)
1" (2.5 cm) diameter
x
1
⁄
4
" (6 mm) deep
4 places
1
⁄
4
" (6 mm)
radius is
permissible
30
11
⁄
32
"
(77.1 cm)
30
11
⁄
32
"
(77.1 cm)
1
3
⁄
4
"
(4.4 cm)
3
1
⁄
8
"
(7.9 cm)
1
3
⁄
16
"
(3 cm)
1
⁄
4
" (6 mm)
radius is
permissible
4
7
⁄
8
"
(12.4 cm)
1
3
⁄
16
"
(3 cm)
3
1
⁄
8
"
(7.9 cm)
1
3
⁄
4
"
(4.4 cm)
14"
(35.6 cm)
This side
facing
interior
This side
facing
interior
16
1
5
⁄
32
"
(2.9 cm)
1
5
⁄
32
"
(2.9 cm)
OVERLAY DOOR PANEL INSTALLATION
Clearance
for hinge
at top and
bottom
Clearance for hinge
at top and bottom
Clearance for
screw head,
4 places
Top of door
Hinge side of door
Clearance for
screw head,
4 places
Figure 18
Right Hand Hinged Door
24" (61 cm) wide appliance
Figure 16
Left Hand Hinged Door
24" (61 cm) wide appliance
Hinge side of door
Top of door
23
3
⁄
4
"
(60.3 cm)
1
⁄
4
"
(6 mm)
Deep
23
3
⁄
4
"
(60.3 cm)
1
⁄
4
"
(6 mm)
Deep
Figure 17
Left Hand Hinged Door
24" (61 cm) wide appliance
1" (2.5 cm) diameter
x
1
⁄
4
" (6 mm) deep
4 places
1
1
⁄
2
"
(3.8 cm)
typical
1
11
⁄
16
"
(4.3 cm)
2"
(5.1 cm)
3
11
⁄
16
"
(9.4 cm)
Figure 19
Right Hand Hinged Door
24" (61 cm) wide appliance
2"
(5.1 cm)
3
11
⁄
16
"
(9.4 cm)
1
1
⁄
2
"
(3.8 cm)
typical
1
11
⁄
16
"
(4.3 cm)
4
7
⁄
8
"
(12.4 cm)
14"
(35.6 cm)
1" (2.5 cm) diameter
x
1
⁄
4
" (6 mm) deep
4 places
1
⁄
4
" (6 mm)
radius is
permissible
30
11
⁄
32
"
(77.1 cm)
30
11
⁄
32
"
(77.1 cm)
1
3
⁄
4
"
(4.4 cm)
3
1
⁄
8
"
(7.9 cm)
1
3
⁄
16
"
(3 cm)
1
⁄
4
" (6 mm)
radius is
permissible
4
7
⁄
8
"
(12.4 cm)
1
3
⁄
16
"
(3 cm)
3
1
⁄
8
"
(7.9 cm)
1
3
⁄
4
"
(4.4 cm)
14"
(35.6 cm)
This side
facing
interior
This side
facing
interior
15
Magnetic Gasket
remove starting at a
corner, grasp and pull
away from the door.
Step 3: Cut and drill the overlay panel
Depending on your model cut the overlay door panel to the
dimensions shown in Figures 16 and 17 for a left hand door
model or Figures 18 and 19 for a right hand door model.
Overlay panel
flush with top
of door.
Holes in
gasket
retainer.
Overlay panel to
be centered on
width of door.
Figure 15
Figure 15a
Step 2: Remove the door gasket
With the door laying on a flat surface and starting at a
corner of the door remove the magnetic door gasket from
the interior side of the door, see Figure 15. Set the gasket
aside on a flat surface.
There are 10 holes in the gasket retainer extrusions, (3 on
each side and 2 at the top and bottom which are used to
fasten the panel to the front of the door. The screws are
provided in the literature pack.
Press and hold down this
tab on the wire connector
and pull the connector apart.
Figure 14
OVERLAY DOOR PANEL INSTALLATION