Monogram ZEU30RSJSS Ficha De Características

Página de 5
Product Specification Revised 4/15
ZEU30RSJSS
Monogram
®
 30" Touch Control Electric Cooktop
NOTES
STANDARD INSTALLATION
19 5/8" 
(49.9) min
19 3/4" 
(50.2) max
Cutout depth
8 1/4"
(21.0) min
6 1/2"
(16.5) min
5"
(12.7) min
16" 
(40.6) min
To electrical junction box
Locate electrical junction box
at least 
16" 
below the countertop
15"
(38.1)
min
13"
(33.0) max
28 1/2" 
(72.4) min
28 5/8" 
(72.7) max
Cutout width
1 3/4" 
(4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" 
(6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
30 " 
(76.2)
Cabinet base
SIDE VIEW
FRONT VIEW
TOP VIEW OF CUTOUT
SIDE VIEW
DRAWER
FRONT
ZEU30RSJSS
NOTES
A   Wall coverings, 
countertop and 
cabinets surrounding 
cooktop must be able to 
withstand temperatures 
of up to 200ºF.
B   Minimum 30" clearance 
from countertop to 
unprotected overhead 
surfaces, when no 
ventilation hood is 
installed.
C   When using a 
ventilation hood above 
the cooktop, see hood 
installation instructions 
for minimum overhead 
clearance dimensions.
D   Minimum 15" of 
clearance from 
countertop to nearest 
overhead surface on 
either side of cooktop. 
Make sure to include 
any lighting rail covers 
in calculation.
E   Minimum 2” distance 
from edge of cutout 
to nearest adjacent 
side wall below upper 
cabinets.
F   Install an approved 
junction box where it 
can be easily reached 
through the front of 
the cabinet where the 
cooktop is located. 
IMPORTANT: For 
serviceability, the 
junction box must be 
located where it will 
allow considerable slack 
in the 48” long conduit.
G   Maximum 13" depth of 
unprotected overhead 
surfaces, when no 
ventilation hood is 
installed.
H   For Americans with 
Disabilities Act (ADA) 
forward approach 
installation: Minimum 
6 1/2" clearance 
between the top of 
the countertop and 
the enclosure. The 
enclosure must be made 
of at least 1/4" thick 
wood material, and 
must have an access 
panel installed in order 
to provide access to  
the junction box and 
hold-down brackets, 
and to allow for service 
of the cooktop.
COUNTERTOP CUT-OUT DIMENSIONS
ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
A
B
C
G
For more details refer to the 
installation instructions for 
this product.
E
D
F
H