Monogram ZHU30RSJSS Ficha De Características

Página de 6
Product Specification Revised 4/15
ZHU30RSJSS
Monogram
®
 30" Induction Cooktop
INSTALLATION
19 1/8" 
(48.6) min
19 1/4" 
(48.9) max
Cutout depth
8"
(20.3) min
5"
(12.7) min
5"
(12.7) min
2"
(5.1) min
Air gap
16" 
(40.6) min
To electrical junction box
Locate electrical junction box
at least 
16" 
below the countertop
15"
(38.1)
min
13"
(33.0) max
33 7/8" 
(86.0) min
34" 
(86.3) max
Cutout width
1 3/4" 
(4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" 
(6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 " 
(91.4)
Cabinet base
SIDE VIEW
FRONT VIEW
TOP VIEW OF CUTOUT
SIDE VIEW
DRAWER
FRONT
ZHU36RSJSS
COUNTERTOP CUT-OUT DIMENSIONS
ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
 
A
B
C
D
E
I
For more details refer to the 
installation instructions for 
this product.
F
H
G
NOTES
NOTES
A   Wall coverings, countertop 
and cabinets surrounding 
cooktop must be able to 
withstand temperatures of up 
to 200ºF.
B   Minimum 30” clearance from 
countertop to unprotected 
overhead surfaces, when no 
ventilation hood or microwave 
oven is installed.
C   When using a ventilation 
hood or microwave oven 
above the cooktop, see hood 
or microwave installation 
instructions for minimum 
overhead clearance 
dimensions.
D   Minimum 15” of clearance 
from countertop to nearest 
overhead surface on both 
sides of cooktop. Make sure to 
include any lighting rail covers 
in calculation.
E   Minimum 2” distance from 
edge of cutout to nearest 
adjacent side wall below upper 
cabinets.
F   Install an approved junction 
box where it can be easily 
reached through the front of 
the cabinet where the cooktop 
is located. IMPORTANT: For 
serviceability, the junction box 
must be located where it will 
allow considerable slack in the 
48” long conduit.
G   Maximum 13” depth of 
unprotected overhead 
surfaces, when no ventilation 
hood or microwave oven is 
installed.
H   When installing the cooktop 
above a cabinet drawer, a 
solid barrier must be installed 
at least 5” from the bottom 
of the cooktop. Use any solid 
material such as 1/4” thick 
plywood. Allow at least 1/4” air 
gap between the barrier and 
the top of the cabinet drawer.
I   For Americans with Disabilities 
Act (ADA) forward approach 
installation: Minimum 5” 
clearance between the top 
of the countertop and the 
enclosure. The enclosure must 
be made of at least 1/4” thick 
wood material, and must have 
an access panel installed in 
order to provide access to the 
junction box and hold-down 
brackets, and to allow for 
service  of  the  cooktop.                                                                                                                                 
For more details refer to the 
installation instructions for this 
product.