Monogram ZEU36RSJSS Instrução De Instalação

Página de 16
WARNING –
 The electrical power to 
the cooktop supply line must be shut off while 
connections are being made. Failure to do so 
could result in serious injury or death.
  When preparing cooktop opening, make sure 
the inside of the cabinet and the cooktop do 
not interfere with each other. (See section on 
preparing the opening.)
  Remove packaging materials and literature 
package from the cooktop before beginning 
installation.
  Be sure to place all literature, Owner’s Manual, 
Installations, etc. in a safe place for future 
reference.
  Make sure you have all the tools and materials 
you need before starting the installation of the 
cooktop.
  Your home must provide the adequate 
electrical service needed to safely and 
properly use your cooktop. (Refer to section on 
electrical requirements.)
3
Installation Instructions
PRE-INSTALLATION CHECKLIST
  When installing your cooktop in your home, 
make sure all local codes and ordinances are 
followed exactly as stated.
  Make sure the wall coverings, countertop and 
cabinets around the cooktop can withstand 
heat (up to 200°F) generated by the cooktop.
  Installing cooktop in combination with other 
products. Both products must be installed 
according to their specific product installation 
instructions. Consideration must be given the 
separate electrical requirements and locations:
 
Over one or two wall ovens:
 
•   Only certain models may be installed over 
wall ovens. The wall oven and cooktop will 
both have a label stating which models are 
approved in combination.
 
Over a Microwave:  
 
•   See microwave installation instructions 
for how to install a microwave under a 
cooktop. For vertical dimension of cooktop, 
see Approximate Cooktop Dimensions 
section.
 
In combination with telescopic downdraft vent:
 
•   See telescopic downdraft vent instructions 
for how to install a vent behind a cooktop.
 
•   The countertop must have a deep flat 
surface to accommodate the combined 
installation of the cooktop and vent.
 
Over a warming drawer:  
 
•   See warming drawer instructions for how to 
install a warming drawer under a cooktop.  
For vertical dimension of cooktop, see 
Approximate Cooktop Dimensions section.
ON
HOT
Cooktop
Literature Package 
(Located under unit)
Foam 
Packaging
PREPARING THE OPENING
1
  The following MINIMUM clearance dimensions 
must be maintained.
13" MAX. Depth of unprotected 
overhead cabinets
30" MIN. 
Clearance from 
countertop to 
unprotected 
overhead 
surface
2" MIN. Clearance from 
cutout to side wall on the 
left of the unit
15" MIN. Height 
from countertop to 
nearest cabinet on 
either side of unit
2" MIN. Clearance 
from cutout to 
side wall on the 
right of the unit
If a 30" clearance between the cooking surface and 
overhead combustible materials or metal cabinets 
cannot be maintained, a minimum clearance of 24" 
is required and the underside of the cabinets above 
the cooktop must be protected with not less than 
1/4" insulating millboard covered with sheet metal 
not less than 0.0122" thick.