Monogram ZEU36RSJSS Ficha De Características
Product Specification Revised 4/15
ZEU36RSJSS
Monogram
®
36" Touch Control Electric Cooktop
NOTES
STANDARD INSTALLATION
19 1/8"
(48.6) min
19 1/4"
(48.9) max
Cutout depth
8 1/4"
(21.0) min
6 1/2"
(16.5) min
5"
(12.7) min
16"
(40.6) min
To electrical junction box
Locate electrical junction box
at least
16"
below the countertop
15"
(38.1)
min
13"
(33.0) max
33 7/8"
(86.0) min
34"
(86.3) max
Cutout width
1 3/4"
(4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2"
(6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 "
(91.4)
Cabinet base
SIDE VIEW
FRONT VIEW
TOP VIEW OF CUTOUT
SIDE VIEW
DRAWER
FRONT
ZEU36RSFSS
NOTES
A Wall coverings,
countertop and
cabinets surrounding
cooktop must be able to
withstand temperatures
of up to 200ºF.
B Minimum 30" clearance
from countertop to
unprotected overhead
surfaces, when no
ventilation hood is
installed.
C When using a
ventilation hood above
the cooktop, see hood
installation instructions
for minimum overhead
clearance dimensions.
D Minimum 15" of
clearance from
countertop to nearest
overhead surface on
either side of cooktop.
Make sure to include
any lighting rail covers
in calculation.
E Minimum 2" distance
from edge of cutout
to nearest adjacent
side wall below upper
cabinets.
F Install an approved
junction box where it
can be easily reached
through the front of
the cabinet where the
cooktop is located.
IMPORTANT: For
serviceability, the
junction box must be
located where it will
allow considerable slack
in the 48" long conduit.
G Maximum 13" depth of
unprotected overhead
surfaces, when no
ventilation hood is
installed.
H For Americans with
Disabilities Act (ADA)
forward approach
installation: Minimum
6 1/2" clearance
between the top of
the countertop and
the enclosure. The
enclosure must be
made of at least 1/4"
thick wood material,
and must have an
access panel installed
in order to provide
access to the junction
box and hold-down
brackets, and to
allow for service of
the cooktop.
COUNTERTOP CUT-OUT DIMENSIONS
ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
A
B
C
D
G
B
H
E
F