BEFORE CALLING FOR SERVICE 
 
Check these helpful tips for any problems with your rangetop. If you need additional help call BlueStar
®
 Customer Service at 1-800-
449-8691. 
 
COOKTOP 
PROBLEM 
POSSIBLE CAUSE 
SOLUTION 
Burner will not ignite – no 
“clicking” sound 
No electrical power to the unit. 
 
Igniter not connected to lead wire. 
 
Igniter not connected to the correct lead wire  
 
Lead wire is worn on chipped. 
 
Lead wire is not connected to spark module. 
 
Plug into a three-prong electrical outlet that is properly grounded. 
 
Check and re-set circuit breaker for the unit. 
 
Connect igniter to orange lead wire.  
 
Connect igniter to the orange lead wire attached to the burner. 
 
Check for signs of wear or chips. Call service. 
 
Call for service. 
 
Burner will not ignite – “clicking” 
sound, but no spark 
 
Gas not turned on 
 
Clogged burner ports 
 
Venturi tube not  aligned with the orifice 
 
Lead wire is in the drip tray 
 
 
Turn on gas supply. 
 
Use a push pin to clear ports. 
 
Position venturi tube over orifice. 
 
Attach lead wire to igniter. 
Burner will not ignite – “clicking” 
sound with spark 
Air shutter needs adjustment. 
 
Gas not turned on 
 
Burner head not in correct location 
 
Faulty igniter (dirty or cracked)  
 
See Top Burner Low Flame Adjustment instructions. 
 
Turn on gas supply. 
 
Identify burners and move them to the correct location. 
 
Burner ignites – “clicking” sound 
does not stop 
Burners are wet 
 
Burner setting too low 
 
Air draft flowing over cooktop 
 
Electrode wires not properly connected 
 
Electric plug not in grounded outlet. 
 
 
Let burners dry and try again. 
 
Turn off, re-ignite and change setting. 
 
Eliminate draft source. 
 
Connect electrode wires.  
Check outlet polarity. 
 
Plug unit into a three-prong electrical outlet that is properly 
grounded. 
Burner doesn’t fully ignite 
Clogged burner ports 
 
Partial gas supply 
 
Burner not properly positioned 
 
Low flame setting needs adjustment 
 
Burner head not in correct location 
 
Use a push pin to clear ports. 
 
Make sure gas supply is fully on. 
 
Check that burner is in the proper location. 
 
See Top Burner Air Shutter Adjustment instructions. 
 
Identify burners and move them to the correct location. 
 
Burner ignition delay – “clicking” 
sound  then ignition whoosh 
 
Air shutter needs adjustment 
 
Turn burner to LOW setting to ignite. 
 
See Top Burner Air Shutter Adjustment instructions. 
 
Lazy flame – floats, larger in size 
than normal 
 
Low propane supply (for LP users) 
 
 
Low flame setting needs adjustment 
 
Fill the propane tank. 
Turn on/off valve fully to on. 
 
See Top Burner Air Shutter Adjustment instructions. 
 
 
Lifting flame – well-defined with 
visible inner core, noisy, gap 
between burner and flame 
Incorrect regulator setting. 
 
Low flame setting needs adjustment 
 
Set regulator to proper setting - Liquid Propane or Natural Gas. 
 
See Top Burner Air Shutter Adjustment instructions.