Preparations of Ductwork and Location  
 
NOTE:  TO  AVOID  DAMAGE  TO  YOUR 
HOOD,  PREVENT  DEBRIS  FROM 
ENTERING THE VENT OPENING. 
 
-  Decide the location of the venting pipe from 
the hood to the outside.  Refer to Figure 1. 
-  A  straight,  short  venting  run  will  allow  the 
hood to perform more efficiently. 
-  Try  to  avoid  as  many  transitions,  elbows, 
and long run as possible.  This may reduce 
the performance of the hood. 
Temporarily  wire  the  hood  to  test  for  proper 
operation before installing.   
Important:  Peel any protective film off the hood
 
Use  duct  tape  to  seal  the  joints  between 
pipe sections.
 
 
Telescopic Stack Installation  
 
1. 
Mark  centerlines  of  cook  top  or  range  on 
ceiling above.  Use centerlines marked on 
ceiling  to  position  the  mounting  template 
as shown in Figure 2.
 
2. 
Remove  and  save  template.    Cut  and 
remove  ceiling  drywall.    Install  2”  x  4” 
cross  framing  lumber  (not  provided) 
between  ceiling  joists.    Refer  to  Figure  3.  
Consult  a  professional  if  you  have 
difficulty or your installation is unique. 
3. 
Finish  the  ceiling  surface.    Be  sure  to 
mark  the  location  of  the  ceiling  joists  and 
cross  framing,  or  replace  the  mounting 
template in the position of the ceiling joists 
& cross framing. 
4. 
Attach  the  telescopic  stack  to  the  ceiling 
and securely fasten to the joists and cross 
framing  with  eight  screws  (not  provided) 
as shown in Figure 3.  Make sure screws 
are  driven  into  center  of  joists  and  cross 
framing for maximum support. 
5. 
Adjust 
the 
telescopic 
stack 
using 
reference  F  calculated  in  Table  1  and 
measurements on page 12.  Tighten from 
the  side  with  four  (4x8  mm)  screws 
(provided) as shown in Figure 3.
 
 
Figure 1 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 