Side burner acceSSory care & uSe/inStallation
  
|
15
BuiLT-in inSTALLATionS
lynx built-in accessories are intended for installation in a 
built-in enclosure constructed of non-combustible materials.
the accessory drops into the opening shown in the cutout 
detail drawing and hangs from its counter-top trim. a deck 
is not required to support it from the bottom. 
pay special attention to the provisions shown for gas line 
hook-up. (see indeX: “cut-out dimensions for Built-in grills 
& accessories”)
installation provisions may be made for the power Burner 
installation. the power Burner cooking height may be 
reduced to better accommodate large cooking pots. 
clearances to combustible material must be maintained 
as outlined below. no combustible material shall be used 
in the construction of a counter top using a recessed 
application.
the enclosure should have ventilation holes to prevent gas 
build-up in the event of a leak. the deck ledges and counter 
should be flat and level. (Refer to ansi Z21.58 standard for 
outdoor cooking gas appliances, section 1.7 enclosures 
for self contained lp-gas supply systems or local codes 
for additional information.) 
the grill accessory may be powered from either a 120 volt, 
60 hertz, 15 amp gfi certified outlet installed by a qualified 
electrician oR it may be powered directly from your lynx 
grill transformer power supply.
When a lynx grill is not available or if the grill is not located 
close enough to the grill a lynx lasK (lynx accessory switch 
Kit) is available as an optional purchase.
CLeArAnCe To ComBuSTiBLe mATeriALS
minimum clearance from the sides and back of the 
accessory to adjacent combustible construction below the 
counter top is 12” from the sides and back. 
Dégagement minimal entre les parois latérales et l’arrière 
de l’appariel et la construction combustible au-dessous 
du panneau supérieur de l’appareil (30 cm à partir des 
parois latérales et 30 cm à partir de l’arrière). 
minimum clearance from sides and back of unit to adjacent 
combustible construction extending above the counter top 
is 18” from the sides and back. 
Dégagement horizontal minimal entre les parois latérales 
et l’arrière de l’appariel et la construction verticale 
combustible au-dessus de l’appareil (45.7 cm à partir des 
parois latérales et 45.7 cm à partir de l’arrière). 
do not use this appliance under overhead combustible 
surfaces. 
Ne pas utiliser cet appareil sous une surface combustible. 
Before you start
...continued