Whirlpool WEG760H0DH Instrução De Instalação

Página de 48
11
Level Range
1. Place level on the oven bottom, as indicated in one of the two 
figures below, depending on the size of the level. Check with 
the level side to side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling 
legs up or down until the range is level.
NOTE: Range must be level for satisfactory baking 
performance and best cleaning results using AquaLift
®
 
Self-Clean Technology.
Make Gas Connection
This range is factory-set for use with Natural gas. To use this 
range with LP gas, see the “Gas Conversions” section before 
connecting this range to the gas supply. Gas conversions from 
Natural gas to LP gas or from LP gas to Natural gas must be 
done by a qualified installer.
Typical Flexible Connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters. See B 
and G in the following illustration. 
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters, 
being certain not to move or turn the gas pressure regulator.
3. Use a 
¹⁵⁄₁₆" (2.4 cm) combination wrench and an adjustable 
wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do 
not make connections to the gas regulator too tight. Making 
the connections too tight may crack the regulator and cause 
a gas leak. Do not allow the regulator to turn when tightening 
fittings. 
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the 
“on” position.
2. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. If bubbles appear, a 
leak is indicated. Correct any leak found.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" 
[1.3 cm] male pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" (1.3 cm) or ¾" (1.9 cm) gas 
pipe
G. Use pipe-joint compound.
H. Adapter
A. Gas pressure regulator shutoff valve
shown in the “on” position
A. Closed valve
B. Open valve
A
B
C
D
E
F
G
H
A