Marvel M36SS Instrução De Instalação

Página de 56
10
Anti - tip Bracket considerations
Figure 9
Figure 8
-Wall stud
-Anti - tip
bracket 
on top of 
cabinet
-At least 2 
screws into 
wall stud.
Crosswise
lumber-
-Leave 
access for 
water line if 
required.
INSTALLING THE CABINET
When planning your rough in opening a 3" (7.6cm) re-
movable filler panel is recommended above the grille. To 
remove the power module from the cabinet the front has to 
be tilted up as shown in Figure 7 when removed for service.
Figure 7
-3" (7.6cm) removable filler 
recommended
84
5
8
"
(214.9cm)
Maximum
Before placing the cabinet in opening, the depth of the 
cut-out opening should be at least 24" (61cm). If the cut-out 
opening depth is more than 24" (61cm), then a piece of 
wood must be secured crosswise on the wall into the studs 
at the height of the anti-tip brackets. (See Figure 9). Slide 
the cabinet into position and level the cabinet with adjust-
able rear roller and front leveling legs. (See Leveling the 
unit on page 11). 
Locate a wall stud behind the unit that is suitable for secur-
ing the 5” (12.7cm) anti-tip bracket to the wall. The position 
of the bracket should be to the right of the power module 
and not behind the power module. Do not disturb the power 
module gasket on the left side of the unit. Place the anti 
tip bracket on top of the cabinet flush with the back of the 
cabinet. Mark and drill at least three holes (
1
8
” (3.2mm) into 
the top of the cabinet and secure the bracket to the top of 
the cabinet with at least (3) of the #8 x 
5
8
” screws provided. 
Secure the bracket to the wall stud with at least (2) #8 x 
1
1
2
” screws provided. See Figure 8.