Thermador DWHD651JFP Instrução De Instalação

Página de 38
7
Electrical Supply
The  customer  has  the  responsibility  of  ensuring  that  the 
dishwasher  electrical  installation  is  in  compliance  with  all 
national  and  local  electrical  codes  and  ordinances.  The 
dishwasher  is  designed  for  an  electrical  supply  of  120V, 
60 Hz, AC, connected to a dishwasher-dedicated, properly 
grounded electrical circuit with a fuse or breaker rated for 15 
amps. Electrical supply conductors shall be a minimum #14 
AWG copper wire rated at 75°C (167°F) or higher. 
Grounding Instructions
The  dishwasher  must  be  properly  grounded  before 
operating.  This  appliance  must  be  connected  to 
a  grounded  metal  permanent  wiring  system,  or  an  
equipment grounding conductor must be run with the circuit 
conductors  and  connected  to  the  equipment  grounding 
terminal  or  lead  on  the  dishwasher.  Make  sure  that  the 
dishwasher is connected to a suitable ground in compliance 
with all local codes or, in the absence of a local code, with 
the NATIONAL ELECTRICAL CODE in the United States or 
the  CANADIAN  ELECTRIC  CODE  C22.1-latest  edition  in 
Canada as well as any provincial/state or municipal or local 
codes that apply.
Electrical Connection
The  dishwasher  electrical  supply  junction  box  (P)  and 
dedicated  receptacle  must  be  mounted  in  an  accessible 
cabinet adjacent to the dishwasher (do not mount the junction 
box or receptacle behind the dishwasher). You will need a 
4
3
/
4
″ x 2
3
/
8
″ (120 x 60mm) opening through the cabinet in 
order to pass the junction box through (see 
Figure 6).  If the 
opening is made through wood, sand it smooth. If the opening 
is made through metal, use the included protective grommet 
(I) or other approved method to protect wiring from damage. 
Use the four screws included (or appropriate fastener) in the 
parts bag to securely mount the junction box so that it can 
be easily accessed (see 
Figure 6). The electrical supply can 
be connected in two ways:
Method A - Three prong plug and receptacle
Use  the  included  three-prong  plug  and  junction  box  to 
connect  to  a  dedicated  household  receptacle.  Make  sure 
the  household  receptacle  meets  the  electrical  supply 
requirements as well as national and local codes.
Electrical Preparation 
     
Avoid Electrical Shock Hazard
Do  not  work  on  an  energized  circuit.  Doing  so 
could  result  in  serious  injury  or  death.  Only 
qualified  electricians  should  perform  electrical 
work. Do not attempt any work on the dishwasher 
electric  supply  circuit  until  you  are  certain  the 
circuit is de-energized.  
Avoid Fire Hazard
Make sure electrical work is properly installed. 
Only qualified electricians should perform 
electrical work.
WARNING
WARNING
Avoid Fire Hazard
Make sure there are no loose electrical connections. 
Make sure all electrical connections are properly 
made. 
WARNING
Dishwasher Electrical Rating
Volts Hertz Amperes Watts
120
60
15
1,450
(max)
12
Figure 6
CLICK
Electrical Preparation
300
Figure 7
P
Dedicated
Receptacle 
or
  
Field Wiring
Dishwasher
Electrical Supply
Junction Box
Electric cord with
junction box and
three prong plug
are included 
with dishwasher