Faber TRAT36SS Ficha De Características

Página de 2
Dimensional Diagrams
 
Ductless
For ducted installations, the 
chimneys can be adjusted 
for ceilings between 7’ 4 
3/8” and 8’ 9 3/8” depend-
ing on the distance between 
the bottom of the hood and 
the cooktop (distance x in  
Ducted diagram).
For ductless installations, 
the chimneys can be adjust-
ed for ceilings between 7’ 9 
1/4” and 8’ 9 3/8” depend-
ing on the distance between 
the bottom of the hood and 
the cooktop (distance x in 
Ductless diagram).
For shorter ceilings, have 
the chimney cover(s) cut at 
a sheet metal shop.    For 
higher ceiling installations, 
the High Ceiling Chimney 
Kit includes a new 40” up-
per chimney which would 
replace the 16 1/8” upper 
chimney that came with the 
hood.
Ducted
Ductless
Ducted
upper 
chimney 
cover
lower 
chimney 
cover
canopy
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
cabinet base
1/8”
 min
16 
1/8”
 max
21 
1/4”
2"
36”
19 
3/8"
x
also consult cooktop
manufacturer's recommendation
min & max ceiling height examples
x = 30"
min
7' 
10 3/8"
max
8' 
9 3/8"
x = 28"
min
7' 
8 3/8"
max
8' 
7 3/8"
x = 26"
min
7' 
6 3/8"
max
8' 
5 3/8"
x = 24"
min
7' 
4 3/8"
max
8' 
3 3/8"
upper 
chimney 
cover
ductless 
lower 
chimney 
cover
canopy
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
cabinet base
10" min
16 
1/8”
 max
21 
1/4"
2"
36”
19 
3/8"
x
also consult cooktop
manufacturer's recommendation
min & max ceiling height examples
x = 30"
min
8' 
3 1/4"
max
8' 
9 3/8"
x = 28"
min
8' 
1 1/4"
max
8' 
7 3/8"
x = 26"
min
7' 
11 1/4"
max
8' 
5 3/8"
x = 24"
min
7' 
9 1/4"
max
8' 
3 3/8"
* it is highly recommended that 
professional style cooking al-
ways be vented to the outside.
WARNING!
 
Product specifications are subject to change without notification.  Consult the installation instructions before you begin installing this rangehood.
Ductless Installations*
For installations where duct-
work is impossible or highly 
impractical, a Ductless 
Conversion Kit
 is available.  
A charcoal filter, which at-
taches under the blower as-
sembly, absorbs smoke and 
odors.  A ductless diverter 
assembly directs the air out 
to a lower chimney with vent 
grates cut into the sides.
Make your ductrun as straight and short as possible.  The ductrun should not ex-
ceed 35 equivalent feet if ducted with the required minimum of 6” round duct.  
Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that there is 
a minimum of 24” of straight duct between elbows if more than one is used. 
Do not install two elbows together. If you must elbow right away, do it as 
far away from the hood’s exhaust opening as possible.
Pre-Planning Your Installation - 
Important: Consult the installation instructions before you begin installing this rangehood.
Pre-Planning Your Installation - 
Important: Consult the installation 
instructions before you begin installing this rangehood.
Rev. 07/11