Monogram ZVC36LSS Instrução De Instalação

Página de 24
16
Installation Preparation
WARNING: 
Disconnect electrical
power from unit before beginning remote control
installation. Failure to do so could result in personal
injury or damage to the electrical controls.
AVERTISSEMENT : 
Il faut
débrancher l’alimentation électrique de l’appareil
avant de commencer l’installation de la commande 
à distance. Il faut suivre cette directive pour éviter
des blessures ou endommager les commandes
électriques.
REMOTE LOCATION FOR CONTROL
The control can be removed from the hood and
installed in a backsplash or countertop. 
• A cover plate is provided to cover the opening in
the hood when the control is removed.
• A 30-ft. length of 4-wire cord is supplied to
accommodate most installations. Because only 
30-ft. of cord is provided, careful consideration
must be given to the location of the remotely
mounted control.
• The 30-ft. cord is supplied with a connector/
converter on one end. DO NOT REMOVE the
connector/converter from the 30-ft. cord. Failure 
to use the connector/converter with the shorter
cord will prevent proper operation of the control.
NOTE: Not for telecommunication (telephone)
network.
• The cord must be routed through the holes in the
insert sleeve, and the rubber grommets put into
place around the cord.
NOTE: On the ZVC30 and ZVC36 models, the cord
needs to be routed through the holes in the insert
sleeve before the damper plate is installed.
• Route the cord through the conduit to reach the
installation location of the control. 
1-11/16
3-11/16
Control cutout
REMOTE MOUNTING OF THE CONTROL – WIRED
Main
PCB
Long cord
Display board
Connector/
converter
Short cord
Remotely Mounted Control—Wall or Countertop Installation