Planning the Installation
 
WARNING
IMPORTANT: Observe all governing codes and ordinances 
during planning and installation. Contact your local building 
department for further information.
Electrical Requirements 
Models ER30D and ER30DSR
It is the owner’s responsibility to ensure that the electrical 
connection of this appliance is performed by a licensed electrician. 
The electrical installation, including minimum supply wire size and 
grounding, must be in accordance with the National Electric Code 
ANSI/NFPA 70-1993* (or latest revision) and local codes and 
ordinances. A copy of this standard may be obtained from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, Massachusetts 02269-9101
• 
The correct voltage, frequency and amperage must be 
supplied to the appliance from a separate, grounded, circuit 
that is protected by a properly sized circuit breaker or time 
delay fuse. Refer to the ratings on the range rating label. If a 
fuse is utilized, fuse both sides of the line (L1 and L2).
ER30D/ER30DSR ELECTRICAL SPECIFICATIONS
Circuit Required
Total Connected Load
240 Vac, 60 Hz, 30 Amp.
5.6 kW (24.2 Amp.)
The ratings above are for reference only - refer to the range 
rating label (see page 3).
• 
The wiring needs to be long enough to allow the range to be  
pulled out for service, while remaining connected.
• 
The wiring connected to the range must:
◊  Have a minimum rating of 250 Volts @ 30 Amp.
◊  Include a strain relief
◊  Be terminated by tinned leads, closed loop terminals or 
open ended spade lugs with upturned ends
◊  Connect to a junction box or receptacle installed by a 
licensed electrician
The appliance may be connected one of the following ways:
• 
Using conduit:
◊  A 4-wire conduit connected to a 4-wire junction box, or
◊  A 3-wire conduit (where local code permits) connected to 
a 3-wire junction box. 
 
 
Suggested conduit wiring color code: black, white, red 
and green.
• 
Using an appliance cord:
◊  A 4-wire appliance cord equipped with a NEMA 14-50P 
plug connected to a NEMA 14-50R receptacle, or
◊  A 3-wire appliance cord (where local code permits) 
equipped with a NEMA 10-50P plug connected to a 
NEMA 10-50R receptacle 
 
 
Appliance cord plug must be UL listed type SRD or 
SRDT. See page 14 for additional details. 
Electrical Requirements
Model ER30D-C
• 
Model ER30ED-C is a freestanding range that comes with 
a factory installed 4-wire appliance cord and NEMA 14-50P 
plug. This wiring configuration is required for freestanding 
ranges installed in Canada, although they may be used 
elsewhere, if local codes 
permit. The plug is designed 
to plug directly into a NEMA 
14-50R electrical receptacle 
installed by a licensed 
electrician according to the 
specifications below. Do not 
modify the factory wiring on 
model ER30D-C.
• 
It is the owner’s responsibility to ensure that the required 
4-wire electrical outlet compatible with the power cord is 
installed by a licensed electrician as specified below prior to 
range installation. The electrical outlet installation, including 
minimum supply wire size and grounding, must be in 
accordance with all governing codes and ordinances.
• 
The correct voltage, frequency and amperage must be 
supplied to the appliance from a separate, grounded, circuit 
that is protected by a properly sized circuit breaker or time 
delay fuse. If a fuse is utilized, fuse both sides of the line (L1 
and L2). Refer to the ratings on the range rating label.
ER30D/ER30DSR ELECTRICAL SPECIFICATIONS
Circuit Required
Total Connected Load
240 Vac, 60 Hz, 30 Amp.
5.6 kW (24.2 Amp.)
The ratings above are for reference only - refer to the range 
rating label (see page 3).
Gas Supply Requirements
(all units)
• 
Check your local building codes for the proper method of 
installation. In the absence of local codes, this appliance 
should be installed in accordance with the National Fuel Gas 
Code ANSI Z223.1.
• 
Be certain that the appliance being installed is correct for 
the gas service provided (natural gas or LP gas). Also, if 
operating the range at an altitude above 4000 ft. (1219 m) 
make sure it is equipped for high altitude operation. Refer 
to the range rating label and the table on page 3 to 
determine the correct model.
• 
See the table below for gas supply pressure requirements.
• 
The regulator inlet accommodates a 3/4” gas line. The range 
ships with a 1/2” to 3/4” adapter connected to the regulator.
GAS SUPPLY PRESSURE REQUIREMENTS
Gas 
Type
Manifold 
Pressure* (WC)
Min. Gas Supply 
Pressure (WC)
Max. Input 
Pressure
Natural
5
6
1/2 psi
LP
10
11
1/2 psi
The ratings above are for reference only - refer to the range rating 
label (see page 3).
NEMA 14-50R Receptacle