Monogram ZET1FHSS Instrução De Instalação

Página de 16
2 B
  CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports 
above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly 
grounded receptacle must be installed. Refer to installation instructions packed with  
the Warming Drawer for specific installation requirements.
Anti-Tip Block Against 
Rear Wall Per Warming 
Drawer Requirement
2" (5.1 cm) 
Min. 
Per Warming 
Drawer 
Requirement
B
F
G
C
A
Recommended 
Cutout Location from 
Floor  
32
1
ø
2
” (82.6 cm)
16
1
ø
4
” (41.3 cm) Min.
Cutout – 
observe all 
dimensions and 
requirements.
Cutout – 
observe all 
dimensions and 
requirements.
30” (76.2 cm) Min. if both ovens are French Door
14” (35.6 cm) Min. if only one oven is French Door
Center Line
Center Line
30” Models
58
1
ø
2
” (148.6 cm) if both ovens are French Door  
42
1
ø
2
” (108 cm) if only one oven is French Door
These ovens 
are not 
approved for 
stackable 
installations.
H
D
E
J
J
Junction 
Box 
Location 
(junction 
box may 
be located 
in adjacent 
cabinet)
22” (55.9 
cm) Min. to 
Bottom of 
Junction 
Box
Cutout Depth  
23
1
ø
2
”  
(59.7 cm) Min.
Opening 
Between Inside 
Walls Must be 
at Least 28
1
ø
2
” 
(72.4 cm) Wide
Side-by-Side Installations
Install two ovens in separate cutouts.
C
2 A
  CUTOUT FOR SINGLE OVENS IN WALL CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim 
both sides equally to establish the cutout width.
K
E
E
L
Dimension
Dimension Description
30” Single Oven
A
Cabinet width
30” (76.2 cm)
B
Cutout width
28
1
ø
2
” (72.4 cm) min. 
28
5
ø
8
” (72.7 cm) max.
C
Cutout height
27
1
ø
4
” (69.2 cm) min. 
27
5
ø
16
” (69.4 cm) max.
D
Overlap of oven over side edges of cutout
11
ø
16
” (1.75 cm)
E
Door swing depth - Allow additional clearances for 
installation and oven usage
16
1
ø
4
” (41.3 cm) min.
F
Overlap of oven top of cutout
1” (2.5 cm) min.
G
Overlap of oven bottom of cutout
1
1
ø
4
” (3.2 cm)
H
Junction box location
9
1
ø
2
” (24.1 cm) max. 
right side only
J
Door swing width - Allow additional clearances for 
installation and oven usage
14” (35.6 cm) min.
K
Countertop or cabinet door protrusion (measure if exist)
Measure “K”
L
Gap between edge of countertop or cabinet door 
to cabinet opening
If K = 0, L = 0, Otherwise 
L = K + 1” (2.54 cm) min.