To Reinstall the Oven Door: 
1. Hold door on both sides. Insert hinges into hinge slots. 
The door will be about halfway open.
It may be necessary to press firmly inward on the lower 
portion of the door, using a rocking motion to fully seat 
the door's hinges.
2. Open door all the way to expose hinge clips. Push 
hinge clips away from you (toward the oven) until they 
meet the hinge.
3. Close and open the door slowly to test the installation. 
It should open and close smoothly and be straight, not 
crooked.
Step 9: Burner Test and 
Adjustment
Install any loose components, such as burner caps and 
grates, that may have been removed earlier. Be certain that 
burner caps seat properly into the burner bases. Before 
testing operation of the appliance, verify that the unit and 
the gas supply have been carefully checked for leaks and 
that the unit has been connected to the electrical power 
supply. Turn the manual gas shut-off valve to the open 
position.
Test Rangetop Burners 
Test Burner Ignition. Select a rangetop burner knob. 
Push in and turn counterclockwise to HI. The ignitor/spark 
module will produce a clicking sound. Once the air has 
been purged from the supply lines, the burner should light 
within four (4) seconds.
Test Flame: High Setting. Turn burner on to HI. See 
Figure 17 for appropriate flame characteristics.
If any of the rangetop burners continue to burn mostly or 
completely yellow, verify that the burner cap is positioned 
properly on the burner base, then retest. If flame 
characteristics do not improve, call Thermador.
Test Flame: Low Setting. Turn burner on to SIM. Verify 
that the flame completely surrounds the burner. There 
should be a flame at each burner port and there should be 
no air gap between the flame and the burner. If any burners 
do not carry over, call Thermador.
The two rangetop burners on the left side feature XLO
causing the flame to cycle on and off when the knob is set 
to the XLO range. This is normal operation.
Repeat the Ignition and Flame Test procedures, described 
above for each rangetop burner.
When Flame is Properly Adjusted: 
There should be a flame at each burner port. There should 
be no air gap between the flame and burner port.
Call Thermador if:
1. Any of the burners do not light.
2. Any of the burners continue to burn yellow.
Photo C: Hinge removed from oven
 Figure 17:  Flame Characteristics
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify
that the regulator is set for the correct fuel. After
adjustment, retest.
Some orange-colored streaking is normal during
the initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate