GE RAB46A Instrução De Instalação

Página de 12
STEP 1 
Preparation of the wall
The wall case should be installed during construction 
and lintels should be used to support the block above 
the wall case. The case will not support the concrete 
block or brick. The case is modular in height and 
width:
Height  — Fits 2 courses concrete block 
— Fits 6 courses standard brick 
— Fits 5 courses jumbo brick
Width  — Fits approximately 2 stud spaces.
For existing construction, wall openings must be
made. Wall openings of the proper dimensions are 
essential to avoid the necessity of fillers or additional 
framing.
STEP 2 
Preparation of the case
If field-supplied case angles are to be used and must 
be installed, proceed as follows:
1. Position the case angles around top and sides 
of the case at the desired location (front to rear) 
with angles facing toward rear (outside). Position 
the case angles vertically on each side of the case 
to provide a level installation.
2. Mark the case through the holes in the case angles.
3. Drill 5/32″ diameter holes at marked locations 
on the case and assemble the angles using only 
10×1/2″ screws. Install the screws from the 
outside of the case.
NOTE: 
Do not drill any holes in bottom of the case.
 
MINIMUM 
 
FINISHED 
 
OPENING 
  DIMENSIONS* 
CASE DIMENSIONS
  Height  Width  Height  Width  Depth
 
 
 
 
 
  15
3
4
26
1
8
15
5
8
″  26
1
16
 
16″
 
2
Roomside
Case
Case angle 
(field-supplied)
Block
Brick
* Dimensions may need to be 
increased to fit unique situations 
in the field if using case angles.
NOTE: 
If an RAB47 or RAB48 or RAK66 Wall Case
Insulation pad is installed, remove it before installing 
the unit.
NOTE: 
Use lintel to support brick, block, etc., above 
the air conditioner case. (If directly under a window 
sill, the use of a lintel may not be necessary.)
“D”*
15
3
4
″ Min.
Main stud
Jack studs
Header—4″ × 4″ or
two 2″ × 4″ on edge
Sub-floor
Jack studs
Cripple
Adjust framing 
to secure this 
dimension
( *See chart 
on page 1)
Finished 
floor
26
1
8
″ Min.