in a Type 1 L.P.   
A Type 1 compatible cylinder with a Type 1 cylinder valve has a back-check valve which does not 
permit gas flow, until a positive seal has been obtained. 
The  cylinder must  be  arranged  for  vapor  withdrawal.  It  must  also  include  a  collar  to  protect  the 
cylinder valve. A safety relief device having direct communication with the vapor space of cylinder 
must be provided. This will expel high pressure gas if the cylinder is overfilled or overheated which 
could result in fire or explosion. 
All L.P. gas cylinders used with this appliance shall be constructed and marked in accordance with 
the  specifications for  L.P.  gas cylinders  of  the U.  S.  Department  of Transportation (DOT)  or  the 
National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for Transportation 
of Dangerous Goods; and Commission, as applicable; and shall be provided with a listed overfilling 
prevention device. 
Read labels on the L.P. Gas Supply Cylinder. 
New cylinders are always shipped empty for safety. 
Allow only qualified L.P. gas dealers to fill or repair your L.P. gas supply cylinder. 
Inform the gas dealer if it is a new or used cylinder to be filled. 
After filling,  have  the  gas  dealer check for  leaks  and  to  see  that  the relief  valve  remains free  to 
function. 
Hose and Regulator (Comes standard with the power burner) 
The Type 1 connection system has the following features: 
The  system  will  not  allow  gas  to  flow  until  a  positive  connection 
has been made. 
NOTE:  The  cylinder  control  valve  must  be  turned  off  before 
any connection is made or removed. 
The system has a thermal element that will shut off the flow of gas 
in the event of a fire. 
The system has a flow limiting device which, when activated, will 
limit the flow of gas to 10 cubic feet per hour. 
NEVER use power burner without leak testing this connection. 
LP (Propane) Gas Supply Connection 
1.  The  tank  valve  should  be  in  the  “OFF”  position.  If  not,  turn  the  knob 
clockwise until it stops.   
2.  Make sure all burner valves are in the “OFF” position.   
3.  Always connect the gas supply regulator as follows:   
Insert the regulator inlet into the tank valve and  turn  the coupling nut 
clockwise  until  the  coupler  tightens  up  (see  picture).  Do  not  over 
tighten  the  coupler.  Turn  the main  tank  valve  on,  remove  the  lid  and 
turn  the  burner  control  valves  on  the  unit  to  the  “HIGH”  position  for 
about 20 seconds to allow the air in the system to purge before attempting to light the burners.