COYOTE CCX2NGFS Manual

Página de 32
 
 
 
9 
Pre-Operation Leak Testing 
DANGER 
3.  Do not insert any tool into the valve outlet or safety relief valve. You may damage the valve and 
cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.   
3.  If a leak is detected at any time or you cannot stop a gas leak, immediately close pipeline valve and 
call LP gas supplier or you fire department!   
3.  Check all gas supply fittings before each use and each time the gas supply cylinder is connected to 
the regulator. Have a qualified service technician leak test the grill any time a part of the gas system 
is replaced. 
WARNING 
Never attempt to attach this grill to the self-contained LP gas system. Do not use grill until leak testing. 
Before Testing 
DO NOT smoke while leak testing. Extinguish all open flames. Never leak test with an open flame. Mix 
a solution of equal parts mild detergent or liquid soap and water. 
 
Leak Testing Valves, Hose and Regulator 
1.    Turn all grill control knobs to OFF. 
2.    Be sure hose is tightly connected to LP tank. 
3.  Completely open LP tank valve by turning cylinder 
valve knob  counterclockwise (right  to  left).  If  you 
hear  a  rushing  sound,  turn  gas  off  immediately. 
There  is  a  major  leak  at  the  connection.  Correct 
before  proceeding  by  calling  franchiser  for 
replacement parts. 
4.    Brush  soapy  solution  onto  areas  where  bubbles 
are shown in LP tank (see picture). 
5.    If “growing” bubbles appear, there is a leak. Close 
LP  tank  valve  immediately  and  retighten 
connections. If leads cannot be stopped do not try to repair. Call franchiser for replacement.   
6.    Always close LP tank valve after performing leak test by turning cylinder valve knob clockwise.       
 
NOTE: 
When leak testing this appliance, make sure to test and tighten all loose connections, including 
the side burner. A slight leak in the system can result in a low flame, or a hazardous condition.   
LP Gas Supply Cylinder Disconnection 
1.  Turn the burner valves off.   
2.  Turn the tank valve off. (Turn clockwise to stop).   
3.  Detach  the  regulator  assembly  from  the  tank  valve  by  turning  the  quick  coupling  nut 
counterclockwise.