Liebherr HC1080 Instrução De Instalação
WARNING
Risk of fire due to refrigerant.
The refrigerant contained within the appliance, R 600a, is
environmentally friendly, but flammable. Leaking refrig-
erant can ignite.
u
Do not damage the pipes of the refrigerant circuit.
WARNING
Danger of fire and damage!
u
Do not place devices that give off heat, e.g. micro-
waves, toasters, etc. on the appliance.
NOTICE
Risk of damage caused by condensation
Installing the appliance next to any other refrigerator or
freezer can cause condensation or damage to the Lieb-
herr appliance.
u
Do not install this appliance next to any other refriger-
ator or freezer except another Liebherr model. Liebherr
models are designed to allow side-by-side installation.
They are equipped with a heating system to eliminate
condensation when refrigerators or freezers are
installed side-by-side.
NOTICE
Risk of damage for the finished floor surface!
u
Protect the finished floor surface before you uncrate the
unit.
WARNING
Danger of damage from overheating. May restrict opera-
tion.
u
Keep ventilation openings, in the appliance enclosure
or in the built-in structure, clear of obstruction.
WARNING
Danger of tilting.
u
To avoid a hazard due to instability of the appliance, it
must be fixed in accordance with the instructions.
q If possible, have a professional install the appliance in
your kitchen cabinet unit.
q If the appliance is damaged check with the supplier
immediately before connecting it.
q The floor of the installation site must be horizontal and
level.
q Do not install the appliance in direct sunlight or next to
an oven, heater or similar heat source.
q Do not install the appliance on your own. It is better to
do this with two or more people.
q In accordance with EN 378 for each 0.28 oz (8 g) of R
600a refrigerant the room where the appliance is
installed must have a volume of 35.5 ft
3
(1 m
3
). If the
installation room is too small an inflammable gas/air
mixture may arise if the refrigerant circuit leaks. You will
find details of the required quantity of refrigerant on the
rating plate inside the appliance.
q If the appliance is installed in a very damp environment
condensate water may form on the outside of the appli-
ance. Always ensure good ventilation.
q The load-bearing capacity of the floor must be sufficient
for the weight of the appliance plus about 1200 pounds
(544 kg) of food weight.
q The electrical socket must assessed precisely to
ensure the correct position and fuse.
q Do not restrict ventilation. Sufficient ventilation is
required for the appliance to operate correctly. The
ventilation grid fitted at the factory guarantees an effec-
tive ventilation gap on the appliance of 31 in.
2
(200 cm
2
). If you replace the ventilation grid with a
fascia, this must have at least the same size or larger
ventilation gap as the manufacturer's ventilation grid.
u
Note down the type (model, number), appliance name,
appliance or serial number, date of purchase and
manufacturer's address in the place provided for this in
the Use & Care Manual.
u
Remove all materials that could prevent it from being
installed properly or prevent proper ventilation from the
back or the side panels of the appliance.
u
Remove the red transport
safety device. Close off any
holes that have been
revealed with plugs (60).
After installation:
u
Remove protective films, adhesive tapes and transport
safety devices, etc.
Note
u
Clean the appliance (see operating instructions,
"Cleaning the appliance" section).
Setting up the device
* Depending on model and options
3