Liebherr HC1080 Instrução De Instalação

Página de 68
WARNING
Risk of fire due to refrigerant.
The refrigerant contained within the appliance, R 600a, is
environmentally  friendly,  but  flammable.  Leaking  refrig-
erant can ignite.
u
Do not damage the pipes of the refrigerant circuit.
WARNING
Danger of fire and damage!
u
Do  not  place  devices  that  give  off  heat,  e.g.  micro-
waves, toasters, etc. on the appliance.
NOTICE
Risk of damage caused by condensation
Installing  the  appliance  next  to  any  other  refrigerator  or
freezer  can  cause  condensation  or  damage  to  the  Lieb-
herr appliance.
u
Do not install this appliance next to any other refriger-
ator or freezer except another Liebherr model. Liebherr
models are designed to allow side-by-side installation.
They are equipped with a heating system to eliminate
condensation  when  refrigerators  or  freezers  are
installed side-by-side.
NOTICE
Risk of damage for the finished floor surface!
u
Protect the finished floor surface before you uncrate the
unit.
WARNING
Danger of damage from overheating. May restrict opera-
tion.
u
Keep  ventilation  openings,  in  the  appliance  enclosure
or in the built-in structure, clear of obstruction.
WARNING
Danger of tilting.
u
To avoid a hazard due to instability of the appliance, it
must be fixed in accordance with the instructions.
q If possible, have a professional install the appliance in
your kitchen cabinet unit.
q If  the  appliance  is  damaged  check  with  the  supplier
immediately before connecting it.
q The floor of the installation site must be horizontal and
level.
q Do not install the appliance in direct sunlight or next to
an oven, heater or similar heat source.
q Do not install the appliance on your own. It is better to
do this with two or more people.
q In accordance with EN 378 for each 0.28 oz (8 g) of R
600a  refrigerant  the  room  where  the  appliance  is
installed  must  have  a  volume  of  35.5  ft
3
  (1  m
3
).  If  the
installation  room  is  too  small  an  inflammable  gas/air
mixture may arise if the refrigerant circuit leaks. You will
find details of the required quantity of refrigerant on the
rating plate inside the appliance.
q If the appliance is installed in a very damp environment
condensate water may form on the outside of the appli-
ance. Always ensure good ventilation.
q The load-bearing capacity of the floor must be sufficient
for the weight of the appliance plus about 1200 pounds
(544 kg) of food weight.
q The  electrical  socket  must  assessed  precisely  to
ensure the correct position and fuse.
q Do  not  restrict  ventilation.  Sufficient  ventilation  is
required  for  the  appliance  to  operate  correctly.  The
ventilation grid fitted at the factory guarantees an effec-
tive  ventilation  gap  on  the  appliance  of  31  in.
2
(200  cm
2
).  If  you  replace  the  ventilation  grid  with  a
fascia, this must have at least the same size or larger
ventilation gap as the manufacturer's ventilation grid.
u
Note down the type (model, number), appliance name,
appliance  or  serial  number,  date  of  purchase  and
manufacturer's address in the place provided for this in
the Use & Care Manual.
u
Remove  all  materials  that  could  prevent  it  from  being
installed properly or prevent proper ventilation from the
back or the side panels of the appliance.
u
Remove  the  red  transport
safety device. Close off any
holes  that  have  been
revealed with plugs (60).
After installation:
u
Remove protective films, adhesive tapes and transport
safety devices, etc.
Note
u
Clean  the  appliance  (see  operating  instructions,
"Cleaning the appliance" section).
Setting up the device
* Depending on model and options
3