Broan EW5636SS Ficha De Características
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
Broan-NuTone Canada Mississauga, Ontario www.broan.ca 877-896-1119
Broan-NuTone Canada Mississauga, Ontario www.broan.ca 877-896-1119
EW56 SERIES WIRING
EW56 SERIES MOUNTING
12”
MAX.
HOOD
CENTERLINE
5”
MAX.
15¼”
24” TO 36”
ABOVE COOKT
OP
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical
This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This appliance
is equipped with a cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is properly
installed and grounded.
Position the electrical outlet within the space covered by the
Position the electrical outlet within the space covered by the
decorative flue and where it will not interfere with the round
duct. Make sure the outlet is no further than 12” from the top
of the hood chasis and that the outlet does not interfere with a
mounting bracket fastening area or where the decorative flue
touches the wall.
1. Construct wood wall framing that is flush with interior
surface of wall studs. Make sure the framing is centered over
installation location.
NOTE
Minimum hood distance above cooktop must not be less
than 24”. A maximum of 36” above the cooktop is highly
recommended for best capture of cooking impurities.
Distances over 36” are at the installer and user’s discretion;
and if ceiling height and flue length permit. 9-ft. to 10-ft. ceilings
may require Flue Extension Model FXNE56SS, depending on
installation heights (purchase separately). See chart below for
than 24”. A maximum of 36” above the cooktop is highly
recommended for best capture of cooking impurities.
Distances over 36” are at the installer and user’s discretion;
and if ceiling height and flue length permit. 9-ft. to 10-ft. ceilings
may require Flue Extension Model FXNE56SS, depending on
installation heights (purchase separately). See chart below for
additional installation height information.
2. After wall surface is finished, fasten (2) 4mm x 38mm screws
at the locations shown above. DO NOT TIGHTEN screws all
the way.
C
L
36” HIGH COOKTOP
13
7
/
8
”
3 ”
4
7
/
16
”
4mm x 38mm
SCREWS
HERE
A
SEE
CHART
BELOW
24"
25"
26"
27"
28"
29"
30"
31"
32"
33"
34"
35"
36"
Ceiling
Height
8 Feet
39-7/8"
40-7/8"
41-7/8"
42-7/8"
43-7/8"
44-7/8"
45-7/8"
46-7/8"
47-7/8"
48-7/8"
*49-7/8"
*50-7/8"
*51-7/8"
9 Feet
**46-7/8" **47-7/8" **48-7/8"
49-7/8"
50-7/8"
51-7/8"
9 Feet
with
FXNE56SS
39-7/8"
40-7/8"
41-7/8"
42-7/8"
43-7/8"
44-7/8"
45-7/8"
10 Feet
with
FXNE56SS
39-7/8"
40-7/8"
41-7/8"
42-7/8"
43-7/8"
44-7/8"
45-7/8"
46-7/8"
47-7/8"
48-7/8"
49-7/8"
50-7/8"
51-7/8"
* Not recommended for non-ducted configuration
** Non-duct recirculation louvers will be exposed in ducted configuration
** Non-duct recirculation louvers will be exposed in ducted configuration
Desired Hood Distance (Above 36" High Cooktop)
Upper Mounting Screws Location (Distance above 36" High Cooktop -
(Dimension “A”)