Planning the Installation
WARNING
IMPORTANT: Observe all governing codes and ordinances
during planning and installation. Contact your local building
department for further information.
Electrical Requirements
Models ER30D and ER30DSR
It is the owner’s responsibility to ensure that the electrical
connection of this appliance is performed by a licensed electrician.
The electrical installation, including minimum supply wire size and
grounding, must be in accordance with the National Electric Code
ANSI/NFPA 70-1993* (or latest revision) and local codes and
ordinances. A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
•
The correct voltage, frequency and amperage must be
supplied to the appliance from a separate, grounded, circuit
that is protected by a properly sized circuit breaker or time
delay fuse. Refer to the ratings on the range rating label. If a
fuse is utilized, fuse both sides of the line (L1 and L2).
ER30D/ER30DSR ELECTRICAL SPECIFICATIONS
Circuit Required
Total Connected Load
240 Vac, 60 Hz, 30 Amp.
5.6 kW (24.2 Amp.)
The ratings above are for reference only - refer to the range
rating label (see page 3).
•
The wiring needs to be long enough to allow the range to be
pulled out for service, while remaining connected.
•
The wiring connected to the range must:
◊ Have a minimum rating of 250 Volts @ 30 Amp.
◊ Include a strain relief
◊ Be terminated by tinned leads, closed loop terminals or
◊ Have a minimum rating of 250 Volts @ 30 Amp.
◊ Include a strain relief
◊ Be terminated by tinned leads, closed loop terminals or
open ended spade lugs with upturned ends
◊ Connect to a junction box or receptacle installed by a
licensed electrician
The appliance may be connected one of the following ways:
•
•
Using conduit:
◊ A 4-wire conduit connected to a 4-wire junction box, or
◊ A 3-wire conduit (where local code permits) connected to
◊ A 4-wire conduit connected to a 4-wire junction box, or
◊ A 3-wire conduit (where local code permits) connected to
a 3-wire junction box.
Suggested conduit wiring color code: black, white, red
and green.
•
Using an appliance cord:
◊ A 4-wire appliance cord equipped with a NEMA 14-50P
◊ A 4-wire appliance cord equipped with a NEMA 14-50P
plug connected to a NEMA 14-50R receptacle, or
◊ A 3-wire appliance cord (where local code permits)
equipped with a NEMA 10-50P plug connected to a
NEMA 10-50R receptacle
Appliance cord plug must be UL listed type SRD or
SRDT. See page 14 for additional details.
Electrical Requirements
Model ER30D-C
•
Model ER30ED-C is a freestanding range that comes with
a factory installed 4-wire appliance cord and NEMA 14-50P
plug. This wiring configuration is required for freestanding
ranges installed in Canada, although they may be used
elsewhere, if local codes
permit. The plug is designed
to plug directly into a NEMA
14-50R electrical receptacle
installed by a licensed
electrician according to the
specifications below. Do not
modify the factory wiring on
model ER30D-C.
•
It is the owner’s responsibility to ensure that the required
4-wire electrical outlet compatible with the power cord is
installed by a licensed electrician as specified below prior to
range installation. The electrical outlet installation, including
minimum supply wire size and grounding, must be in
accordance with all governing codes and ordinances.
•
The correct voltage, frequency and amperage must be
supplied to the appliance from a separate, grounded, circuit
that is protected by a properly sized circuit breaker or time
delay fuse. If a fuse is utilized, fuse both sides of the line (L1
and L2). Refer to the ratings on the range rating label.
ER30D/ER30DSR ELECTRICAL SPECIFICATIONS
Circuit Required
Total Connected Load
240 Vac, 60 Hz, 30 Amp.
5.6 kW (24.2 Amp.)
The ratings above are for reference only - refer to the range
rating label (see page 3).
Gas Supply Requirements
(all units)
•
Check your local building codes for the proper method of
installation. In the absence of local codes, this appliance
should be installed in accordance with the National Fuel Gas
Code ANSI Z223.1.
•
Be certain that the appliance being installed is correct for
the gas service provided (natural gas or LP gas). Also, if
operating the range at an altitude above 4000 ft. (1219 m)
make sure it is equipped for high altitude operation. Refer
to the range rating label and the table on page 3 to
determine the correct model.
•
See the table below for gas supply pressure requirements.
•
The regulator inlet accommodates a 3/4” gas line. The range
ships with a 1/2” to 3/4” adapter connected to the regulator.
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural
5
6
1/2 psi
LP
10
11
1/2 psi
The ratings above are for reference only - refer to the range rating
label (see page 3).
NEMA 14-50R Receptacle