Summit SBC635MBINK Manual Do Proprietário

Página de 44
 
SAFETY PRECAUTIONS: ELECTRICAL MATTERS 
1.  Do not pull on the power cord when unplugging the machine. Grasp the plug firmly and pull it straight 
out of the socket. Do not pull the plug with wet hands. 
2.  Keep the power cord at the back of the appliance to avoid tripping accidents or damage to the cord. 
3.  If the power cord is damaged or frayed, it must be replaced by a qualified service professional. 
4.  Use only a standard three-hole grounded power socket rated above 10A. The socket should not be 
shared with other appliances. 
5.  Be sure the plug fits firmly into the socket and that the socket is grounded. 
6.  The use of an extension cord is NOT recommended. 
7.  The beer dispenser requires an AC power supply of 110~120V/60Hz and pulls a current of over 10A. 
The fuse or circuit breaker should be rated at 15A. 
8.  If the leakage of a combustible gas is detected, turn off the gas valve and open the doors and 
windows. To reduce the risk of fire caused by a spark, do not pull out the plug of the beer dispenser or 
of any other electrical device.  
SAFETY PRECAUTIONS: CO
2
 (CARBON DIOXIDE) GAS 
Always connect the CO
2
 cylinder to a regulator!  Failure to do so may cause an explosion resulting in 
possible injury or death when the cylinder valve is opened. 
Never connect the CO
2
 cylinder directly to the product container. 
Always keep CO
2
 cylinders away from heat.  Store extra cylinders in a cool place (preferably below 
70°F).  Securely fasten cylinders with a chain in an upright position when storing. 
Never drop or throw a CO
2
 cylinder. 
Always check the D.O.T. (Department of Transportation) test date on the cylinder neck before 
installation.  If it has been more than 5 years, do not use.  Return the cylinder to your gas supplier. 
Never connect a product container unless there are at least two safety devices in the pressure system: 
one on the CO
2
 regulator and the other on the product container or in the pressurized gas line. 
The recommended pressure for the CO
2
 system is 8-10 lbs. 
 
SAVE THESE INSTRUCTIONS 
 
 
 
 
 
Model SBC635MBI is designed for indoor use and can be installed 
either built-in or free-standing. 
Model SBC635MOS can be installed in an outdoor environment. It 
can only be installed free-standing. Do not use under a bar or 
counter. This model is equipped with a GFCI (ground-fault circuit 
interrupter) plug, a safety device that cuts off electricity to the unit if 
the power line gets wet. 
To save energy and maintain optimum performance: 
When positioning the OS unit: Allow at least 4 inches of clearance at 
the top, on the sides and in the rear for sufficient airflow.