Dacor RGC304SLPH Instrução De Instalação
3
Installation Specifications
WARNING
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
Electrical Requirements
WARNING
To prevent an electric shock hazard, the power supply
must meet the specifications stated below. It is the own-
er’s responsibility to make sure that the electrical service
meets electrical requirements and that the electrical outlet
has been properly installed.
The cooktop is supplied with a factory installed,
•
40-inch, three prong, grounding electrical plug. It is
connected to the chassis at the bottom right rear cor-
ner. It must be connected to a dedicated, grounded
three prong electrical outlet installed by a licensed elec-
trician.
The electrical installation, including minimum supply
The electrical installation, including minimum supply
•
wire size and grounding, must be done in accordance
with National Electric Code ANSI/ NFPA 70* and local
codes and ordinances. A copy of this standard may be
obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
The correct voltage, frequency, and amperage must be
The correct voltage, frequency, and amperage must be
•
supplied to the electrical outlet according to the product
data label located on the bottom of the chassis. See
the table below for reference.
Be certain to locate the electrical outlet so that the
Be certain to locate the electrical outlet so that the
•
power cord may be easily disconnected if the unit
needs service.
Do not plug the cooktop into a ground fault interrupter
Do not plug the cooktop into a ground fault interrupter
•
(GFI) electrical outlet.
Gas Supply Requirements
Be certain that the cooktop being installed is correct for
•
the gas service being provided (natural gas or LP gas).
Also, if operating the cooktop at an altitude above 4000
ft. (1219 m) make sure it is equipped for high altitude
operation.
Units equipped for LP operation have “LP” in the model
Units equipped for LP operation have “LP” in the model
•
number listed on the product data label. See the dia-
gram below for label location.
Units equipped for high altitude operation have an “H”
Units equipped for high altitude operation have an “H”
•
at the end of the model number listed on the product
data label.
Check your local building codes for the proper method
Check your local building codes for the proper method
•
of installation. In the absence of local codes, this
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54.
See the product data label for gas supply pressure
See the product data label for gas supply pressure
•
requirements or the table below for reference. Make
sure the gas supply meets minimum requirements.
An external manual shut-off valve must be installed
An external manual shut-off valve must be installed
•
between the gas inlet and the cooktop, for the purpose
of turning on or shutting off gas to the appliance.
The cooktop comes from the factory with a regulator in
The cooktop comes from the factory with a regulator in
•
the shipping carton. Use only the regulator provided.
The regulator must be installed in the gas line that runs
from the cooktop gas inlet to the gas shut off valve.
The regulator inlet accommodates a 3/4” gas line. The
The regulator inlet accommodates a 3/4” gas line. The
•
inlet to the cooktop itself is equipped with a 3/4” male
NPT fitting.
The cooktop gas and electrical connections are located on
the bottom of the cootktop in the back right corner as you
face the front of the unit. See the diagram below.
Product Data Label
Gas Inlet Electric Cord
Front of unit
Chassis Bottom
RGC304
RGC365
RGC304LP
RGC365LP
Total Connected
Load
0.25 Amps
(0.03 kW)
0.25 Amps
(0.03 kW)
Circuit
Requirement
120 Vac,
60 Hz, 15 Amp
120 Vac,
60 Hz, 15 Amp
Gas Type
Natural
LPG
Manifold
Pressure
5” Water
Column
10” Water Column
Min. Gas Supply
Pressure
6” Water
Column
11” Water Column
Gas and Electrical Requirements*
* The data above is for reference only. If the above data
does not agree with the product data label, use the data on