Dacor RGC304SLPH Instrução De Instalação

Página de 16
3
Installation Specifications
 WARNING
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information.
Electrical Requirements
 WARNING
To prevent an electric shock hazard, the power supply 
must meet the specifications stated below. It is the own-
er’s responsibility to make sure that the electrical service 
meets electrical requirements and that the electrical outlet 
has been properly installed.
The cooktop is supplied with a factory installed, 
40-inch, three prong, grounding electrical plug. It is 
connected to the chassis at the bottom right rear cor-
ner. It must be connected to a dedicated, grounded 
three prong electrical outlet installed by a licensed elec-
trician.
The electrical installation, including minimum supply 
wire size and grounding, must be done in accordance 
with National Electric Code ANSI/ NFPA 70* and local 
codes and ordinances. A copy of this standard may be 
obtained from:
 
National Fire Protection Association 
 
1 Batterymarch Park  
 
Quincy, MA 02269-9101
The correct voltage, frequency, and amperage must be 
supplied to the electrical outlet according to the product 
data label located on the bottom of the chassis. See 
the table below for reference.
Be certain to locate the electrical outlet so that the 
power cord may be easily disconnected if the unit 
needs service.
Do not plug the cooktop into a ground fault interrupter 
(GFI) electrical outlet.
Gas Supply Requirements
Be certain that the cooktop being installed is correct for 
the gas service being provided (natural gas or LP gas). 
Also, if operating the cooktop at an altitude above 4000 
ft. (1219 m) make sure it is equipped for high altitude 
operation.
Units equipped for LP operation have “LP” in the model 
number listed on the product data label. See the dia-
gram below for label location.
Units equipped for high altitude operation have an “H” 
at the end of the model number listed on the product 
data label.
Check your local building codes for the proper method 
of installation. In the absence of local codes, this 
appliance should be installed in accordance with the 
National Fuel Gas Code ANSI Z223.1/NFPA 54.
See the product data label for gas supply pressure 
requirements or the table below for reference. Make 
sure the gas supply meets minimum requirements.
An external manual shut-off valve must be installed 
between the gas inlet and the cooktop, for the purpose 
of turning on or shutting off gas to the appliance.
The cooktop comes from the factory with a regulator in 
the shipping carton. Use only the regulator provided. 
The regulator must be installed in the gas line that runs 
from the cooktop gas inlet to the gas shut off valve.
The regulator inlet accommodates a 3/4” gas line. The 
inlet to the cooktop itself is equipped with a 3/4” male 
NPT fitting.
The cooktop gas and electrical connections are located on 
the bottom of the cootktop in the back right corner as you 
face the front of the unit. See the diagram below.
Product Data Label
Gas Inlet Electric Cord
Front of unit
Chassis Bottom
RGC304 
RGC365
RGC304LP 
RGC365LP
Total Connected 
Load
0.25 Amps
(0.03 kW)
0.25 Amps
(0.03 kW)
Circuit 
Requirement
120 Vac,
60 Hz, 15 Amp
120 Vac,
60 Hz, 15 Amp
Gas Type
Natural
LPG
Manifold 
Pressure
5” Water 
Column
10” Water Column
Min. Gas Supply 
Pressure
6” Water 
Column
11” Water Column
Gas and Electrical Requirements*
* The data above is for reference only. If the above data 
does not agree with the product data label, use the data on 
the product data label.