Gas Connection
 WARNING
Make sure the gas supply valve is off and that the power to 
the range is turned off at the circuit breaker or fuse box prior 
to connecting the gas line.
Do not apply excessive pressure when tightening gas 
connections and fittings.
Do not use Teflon tape or plumber’s putty on gas flex line 
connections.
Check for gas leaks as instructed below before using the 
appliance. Do not use a flame to check for leaks.
For LP installations, the LP gas tank must have its own 
high pressure regulator. This is in addition to the pressure 
regulator provided with the range.
The maximum gas supply pressure to the regulator must 
never exceed 1/2 pound per square inch (p.s.i.) or 3.5kPa.
The range and shut-off valve must be disconnected from the 
gas supply piping during any pressure testing exceeding 1/2 
p.s.i. (3.5 kPa).
The range must be isolated from the gas supply piping by 
closing the shut-off valve during any pressure testing at or 
below 1/2 p.s.i. (3.5 kPa).
Be careful not to damage the wires inside the chassis while 
pushing the gas line through the access holes.
NOTE: The gas pressure regulator is pre-set at the factory for 
the type of gas intended for use with the appliance. To verify that 
the appliance is compatible with the type of gas available, check 
the product data label (see page 3 for location). Ranges intended 
for use with LP gas will have “LP” as a part of the model number. 
Consult your dealer if the range is not compatible with the type of 
gas supplied.
Make sure the gas supply valve is in the off position and 
1. 
power to the range is off.
Connect a flexible gas supply line to the gas shut-off valve 
2. 
previously installed on the stub out. The gas line needs to be 
long enough to allow the range to be pulled out for service.
Slide the gas line up through the access holes in the chassis 
3. 
and up to the regulator. Move the wires around inside the 
access holes to prevent them from catching on the gas line 
as you push it up.
Connect the gas line to the regulator.
4. 
Turn all cooktop 
5. 
control valves to the 
OFF position.
Turn on the gas 
6. 
supply and check all 
lines and connections 
for leaks using a soap 
and water solution.
Turn the gas shut-
7. 
off valve to the off 
position.
Installation Instructions
OFF Icon
Bare wire 
connections
Loop and  
spade terminal 
connections
L1 terminal
L2 terminal
L1 wire
White wire
L2 wire
Strain relief
Neutral terminal
Neutral to ground 
jumper link
3-wire Appliance Cord 
Connection - 
Where Local Code Permits
L1
Neutral
L2
10-50P Plug
Gas 
line
Regulator 
connection
Access 
holes
Back of range