WHEN FLAME IS PROPERLY ADJUSTED:
•
There should be a flame at each burner port.
•
There should be no air gap between the flame and
burner port.
burner port.
Call Thermador if:
1. Any of the burners do not light.
2. Any of the burners continue to burn yellow.
1. Any of the burners do not light.
2. Any of the burners continue to burn yellow.
Installer Checklist
Final Check List
•
Cooktop correctly positioned in countertop recess.
•
Specified clearances maintained to cabinet surfaces.
•
Burner caps positioned properly on burner bases.
•
All packaging material removed.
•
Island Trim or Backguard attached according to
instructions.
instructions.
•
The griddle plate tilted slightly forward. (See “Griddle
Tilt Adjustment (not all models)” on page 10.)
Tilt Adjustment (not all models)” on page 10.)
Gas Supply
•
Connection: 1/2" NPT with a minimum 3/4" diameter
flex line.
flex line.
•
If converting from natural to LP gas, refer to LP
Conversion Instructions for details.
Conversion Instructions for details.
•
Manual gas shut off valve installed in an accessible
location (without requiring removal of appliance).
location (without requiring removal of appliance).
•
Unit tested and free of gas leaks.
Electrical
•
For models with the electric griddle, a polarized and
grounded 120VAC receptacle with 15 AMP over
current protection is provided for service cord
connection.
grounded 120VAC receptacle with 15 AMP over
current protection is provided for service cord
connection.
Operation
•
All internal packing materials removed. (Check below
grates and grill pans.)
grates and grill pans.)
•
Bezels centered on burner knobs, and knobs turn
freely.
freely.
•
Purge air from gas system by operating one of the top
burners for several minutes.
burners for several minutes.
•
Each burner lights satisfactorily, both individually and
with other burners operating.
with other burners operating.
•
Burner grates are correctly positioned.
Installer
•
Give CARE and USE MANUAL and INSTALLATION
INSTRUCTIONS to your customer.
INSTRUCTIONS to your customer.
Figure 12: Flame Characteristics
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment,
retest.
Some orange-colored streaking is normal during the
initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate before
making adjustments.
regulator is set for the correct fuel. After adjustment,
retest.
Some orange-colored streaking is normal during the
initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate before
making adjustments.
Yellow Flames:
Further adjustment is required.
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
Normal for Natural Gas.