Dacor DRT304SNGH Instrução De Instalação

Página de 16
4
Cabinet and Countertop Layout
 WARNING
To avoid the risk of fire or personal injury, all minimum  
and maximum specified clearances on this and the 
following pages must be maintained or exceeded.
General Considerations
The minimum distance from the back of the cooktop 
to a combustible rear wall is 2 1/2” (64 mm) minimum 
(Figure 1).
Installation of a non-combustible material* (up to the 
hood) or a backsplash is always recommended, and 
mandatory if the distance to the back wall from the 
cooktop is less than 2 1/2” (Figure 2). When installing 
a backguard, use only Dacor model numbers AEB3009 
or AEB3012 (for model DRT304S) AEB3609, AEB3612 
(for model DRT366S).
* Consult local codes and ordinances for acceptable 
non-combustible materials.
Carefully check the location where the cooktop is to be 
installed. For best performance, the cooktop should be 
installed away from drafts caused by doors, windows 
and heating and air conditioning outlets. To reduce the 
risk of personal injury from reaching over a hot appli-
ance, avoid cabinet installations directly above.
Installation Requirements
To reduce the risk of personal injury and to reduce 
accumulated smoke in the room, Dacor strongly recom-
mends installing a range hood. A hood should project 
forward a minimum of five (5) inches beyond the face 
of the cabinets.
The installation must allow access to the underside 
of the cooktop for service and inspection purposes, 
including the ability to turn off the cooktop gas supply 
valve and electrical outlet.
All contact surfaces between the cooktop and the coun-
ter must be solid and level.
The countertop overhang on the sides of the cutout 
shown on the following pages covers the recessed por-
tions of the cooktop behind the control panel and cre-
ates a seamless look for the installation.
IMPORTANT: 
When installing the cooktop into a lami-
nated or synthetic countertop, radius the corners of the 
cutout to help avoid cracking. Consult the countertop 
manufacturer’s instructions for minimum corner radius, 
reinforcement and heat protection requirements.
Gas and Electric Service Location
The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so they do not interfere 
with the cooktop when it is installed. If installing another 
appliance in the cabinet below, allow for the routing of 
gas and electrical service out the back of the unit.
The shaded area on the facing page shows the rec-
ommended location of the gas inlet and the electrical 
outlet. For replacement purposes, the location of the 
existing utilities may be utilized provided they do not 
interfere with the sides or rear of the cooktop. Check 
local building codes for permissible utility locations.
For best performance and to minimize gas pressure 
loss, attach the gas supply regulator as close as pos-
sible to the cooktop gas inlet.
The installation must:
Allow for access to the gas shut-off valve and regulator 
when the unit is installed.
Allow for access to the electrical outlet, when the 
cooktop is in place so that the power cord may be eas-
ily disconnected if the unit needs service.
Allow the (32”) power cord to reach the electrical outlet.
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
Combustible
rear wall
2 1/2” (64 mm) Min. to
combustible rear wall
FIGURE 1