Dacor DHW361 Guia Do Desenho

Página de 1
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DHW
Discovery
®
 30”, 36”, 42” and 48” Wide
Wall Mount Chimney Hoods
Document # PG07-001
Revised 10/27/14   Page 1/1
DHW SERIES OVERALL DIMENSIONS
Chimney 
24”
(61.0 cm)
Min. 30 1/4” (76.8 cm) Max. 42” (106.7 cm)
30” - 36” - 42” - 48”
15”
(38.1 cm)
11 3/4”
(29.8 cm)
5 3/4”
(14.6 cm)
12 1/2” (31.8 cm)
16 1/4” * (41.3 cm)
Blower
600 CFM* (1200 CFM* for units with 2 blowers) 
with electronic speed control
Blower speeds
4
Lights
12 Vac, 20 Watt halogen
Filters
Baffle type, dishwasher safe
Exhaust
8 inch
Finish
430 stainless steel
Total connected 
load 
120 Vac, 60 Hz.  
(see table at right for current rating)
Circuit 
requirements
120 Vac, 15 Amp. grounded, dedicated 3-wire 
circuit (hot, neutral, ground)
* At zero inches static pressure
MODEL NUMBER
DHW301
DHW361
DHW421
DHW482
Blowers
1
1
1
2
Lights
2
3
4
Filters
1
1
1
2
Maximum 
current draw
3.4 Amp.
3.4 Amp.
3.6 Amp.
6.8 Amp.
IMPORTANT: The minimum installed distance from the hood to the cooking 
surface must be no less than 30 inches. The minimum specified distance 
may be higher for the particular range or cooktop in use. Check the 
manufacturers specifications for the cooktop or range. 
* 18” 1/4 on 48 inch model (DHW482)
GENERAL SPECIFICATIONS
MODEL SPECIFIC SPECIFICATIONS
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
 WARNING
•  Observe all governing codes and ordinances during planning 
and installation. Contact your local building department for 
further information.
•  This appliance must be installed in accordance with the 
accompanying installation instructions.
•  DO NOT install an additional in-line or external blower to 
increase the length of the duct run. Even small differences 
between blower air flow rates can greatly reduce the air draw 
of the hood.
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the 
actual maximum duct run, subtract the equivalent length of each elbow, 
transition and cap from 50 feet. See the Duct Planning Guide or the 
installation instructions for more details.
REAR EXHAUST DIAGRAM
 
Chimney can accommodate up to 10” round 
duct work
 
Unit can be installed to exhaust through the 
ceiling or through the rear wall (see diagram 
below).
Optional Recirculation Kit 
(PN AVDH1/AVDH2)
Converts hood to a recirculating 
configuration in instances where 
exhausting the hood outside the 
building is not practical or desired. 
Consists of a top cap and 2 
charcoal filters. When installed, 
the top cap redirects air flow out 
the vents in the sides of the hood 
chimney assembly. The provided 
charcoal filters are installed 
underneath the mesh type filters 
included with the hood. The  
charcoal filters reduce smoke and 
fumes before the hood exhaust 
is vented into the room. Requires 
25 inch long piece of 8 inch round 
duct (not included).
Top cap
8 inch 
duct