Best WCPI Guia Da Instalação

Página de 2
WCPI W
ALL
C
ONTROL
I
NSTALLATION
I
NSTRUCTIONS
F
OR USE WITH
B
EST
PIK33 
AND
B
EST
PIK45 
INSERT MODELS ONLY
I
NSTALLATION DU CONTRÔLE MURAL
WCPI
N
E CONVIENT QU
AUX MODULES DE HOTTE ENCASTRABLE DE MODÈLE
B
EST
PIK33 
ET
B
EST
PIK45 
SEULEMENT
I
NSTRUCCIONES PARA LA INSTALACIÓN DEL CONTROL MURAL
WCPI
P
ARA UTILIZAR CON LOS MODELOS DE MÓDULO DE CAMPANA EMPOTRABLE
B
EST
PIK33 
Y
B
EST
PIK45 
ÚNICAMENTE
E
NGLISH
R
EAD AND SAVE THESE INSTRUCTIONS
- I
NSTALLER
: L
EAVE THIS INSTRUCTION SHEET WITH THE HOMEOWNER
.
T
HIS KIT CONTAINS
:     • O
NE
WCPI 
REMOTE CONTROL
• O
NE ELECTRICAL CONNECTOR
1. T
URN OFF POWER AND LOCK OUT SERVICE PANEL BEFORE WIRING CONTROL
2. R
EMOVE THE
SCREWS RETAINING THE SMALL PLATE COVERING THE ELECTRICAL HARNESS ACCESS ON THE INSERT
. (S
EE FIGURE
쐃.
)
3. R
EMOVE WIRING KNOCKOUT AND INSTALL APPROVED ELECTRICAL CABLE CLAMP
(
NOT SUPPLIED
). (S
EE FIGURE
쐇.
)
4. P
ASS A
3-
WIRE PLUS GROUND ELECTRICAL CABLE
(
NOT SUPPLIED
THROUGH THE CABLE CLAMP
.
5. R
EMOVE AND DISCARD THE CONNECTOR
(A
AT THE END OF THE INSERT ELECTRICAL HARNESS
. (S
EE FIGURE
쐋.
)
6. C
ONNECT THE ELECTRICAL CABLE TO THE WIRES OF THE NEW CONNECTOR
(
PROVIDED
USING WIRE CONNECTORS
(
NOT SUPPLIED
AS FOLLOWS
: WHITE
TO
BROWN (B), BLACK 
TO
BLACK (C) and RED
TO
RED (D). P
LUG THE NEW CONNECTOR TO THE INSERT HARNESS
. (S
EE FIGURE
쐏.
)
7. C
ONNECT THE CABLE
BARE or GREEN WIRE 
UNDER THE
GREEN 
GROUND SCREW
(E
INSIDE THE INSERT
. (S
EE FIGURE
쐏.
)
8. R
EINSTALL THE SMALL PLATE COVERING THE ELECTRICAL HARNESS
.
9. S
ELECT THE LOCATION FOR THE WALL CONTROL
.
10. R
OUTE THE ELECTRICAL CABLE FROM THE INSERT TO THE WALL CONTROL LOCATION
.
11. R
EMOVE THE FACEPLATE FROM THE WALL CONTROL BY REMOVING TWO SCREWS
. (S
EE FIGURE
쐄.
)
I
F FINISHED WALL IS NOT IN PLACE
12. R
EMOVE
TABS
(F
ALONG TOP AND BOTTOM EDGES OF THE CONTROL OUTLET BOX
(
PROVIDED
). R
EMOVE ONE OF THE
WIRING KNOCKOUTS
(G
OR
(H
AND INSTALL APPROVED ELECTRICAL CABLE CLAMP
(
NOT
SUPPLIED
). (S
EE FIGURE
쐂.
)
13. P
OSITION THE CONTROL OUTLET BOX SO THAT BOTH FACE PLATE MOUNTING TABS ARE FLUSH TO THE FINISHED WALL SURFACE
. F
ASTEN ONE SIDE
(
LEFT OR RIGHT
TO A WALL STUD USING THREE SCREWS
(
NOT
SUPPLIED
).
14. P
ASS THE ELECTRICAL CABLE THROUGH THE CABLE CLAMP AND TIGHTEN SECURELY
I
F FINISHED WALL IS IN PLACE
12. C
UT A LEVEL
5 1/2” 
X
3 1/4” 
HOLE IN THE LOCATION SURFACE
NOTE: I
F POSSIBLE
LOCATE THE HOLE BESIDE A WALL STUD
(
LEFT OR RIGHT
FOR FASTENING
. (S
EE FIGURE
�.
)
13. R
EMOVE
THE
WIRING
KNOCKOUT
(G
FROM
THE
BACK
SURFACE
OF
THE
CONTROL
OUTLET
BOX
AND
INSTALL
APPROVED
ELECTRICAL
CABLE
CLAMP
(
NOT
SUPPLIED
). 
P
ASS THE ELECTRICAL CABLE THROUGH THE CABLE CLAMP AND TIGHTEN SECURELY
. (S
EE FIGURE
쐂.
)
14. P
OSITION THE CONTROL OUTLET BOX
(
PROVIDED
IN HOLE AND FASTEN ONE SIDE
(
LEFT OR RIGHT
TO A WALL STUD USING THREE SCREWS
(
NOT SUPPLIED
). I
F CONTROL
OUTLET BOX CANNOT BE FASTENED TO A WALL STUD
ATTACH BOX TO FINISHED WALL USING SWITCH BOX SUPPORT BRACKETS
(
NOT SUPPLIED
AVAILABLE AT MOST
HARDWARE STORES
). T
HESE BRACKETS SLIDE IN BESIDE THE CONTROL OUTLET BOX
(
BOTH LEFT AND RIGHT SIDE
), 
HOOKING BEHIND THE FINISHED WALL
. B
END THE
PROTRUDING TABS OVER INTO THE BOX TO SECURE IT
.
C
ONTINUE AS FOLLOWS
15. U
SING WIRE CONNECTORS
(
NOT SUPPLIED
), 
CONNECT CABLE WIRES TO CONTROL WIRES AS FOLLOWS
: WHITE
TO
BROWN (B), BLACK
TO
BLACK (C), RED
TO
RED (D) , BARE or GREEN wire 
UNDER
GREEN 
GROUND SCREW
(E). (S
EE FIGURE
�.
)
16. R
EINSTALL THE CONTROL FACEPLATE
ENSURING NOT TO PINCH WIRES
.
17. R
ESTORE POWER AND TEST CONTROLS
. F
OR WIRING DIAGRAM
SEE THE BACK OF THIS PAGE
.
F
RANÇAIS
L
IRE ET CONSERVER CES INSTRUCTIONS
- I
NSTALLATEUR
: L
AISSER CETTE FEUILLE D
INSTRUCTION AU PROPRIÉTAIRE
.
C
ET ENSEMBLE COMPREND
:
•  U
N CONTRÔLE À DISTANCE
WCPI
• U
N CONNECTEUR ÉLECTRIQUE
1. C
OUPER L
ALIMENTATION ÉLECTRIQUE AU PANNEAU DE SERVICE ET LE VERROUILLER AVANT D
EFFECTUER LE BRANCHEMENT DU CONTRÔLE À DISTANCE
.
2. R
ETIRER LES QUATRE VIS QUI RETIENNENT LA PETITE PLAQUE RECOUVRANT L
ACCÈS AU HARNAIS ÉLECTRIQUE DU MODULE DE HOTTE ENCASTRABLE
. (V
OIR FIGURE
쐃.
)
3. O
UVRIR L
ENTRÉE DÉFONÇABLE ET Y INSTALLER UN SERRE
-
FILS APPROUVÉ
(
NON INCLUS
). (V
OIR FIGURE
쐇.
)
4. P
ASSER UN FIL ÉLECTRIQUE TROIS BRINS
(
PLUS FIL DE MISE À LA TERRE
) (
NON INCLUS
À TRAVERS LE SERRE
-
FILS
.
5. E
NLEVER ET JETER LE CONNECTEUR
(A
QUI SE TROUVE À L
EXTRÉMITÉ DU HARNAIS ÉLECTRIQUE
. (V
OIR FIGURE
쐋.
)
6. À 
L
AIDE DE CONNECTEURS
(
NON INCLUS
), 
EFFECTUER LA CONNEXION DU FIL ÉLECTRIQUE AUX FILS DU NOUVEAU CONNECTEUR
(
INCLUS
COMME SUIT
: BLANC 
AVEC
BRUN (B), NOIR
AVEC
NOIR (C
et ROUGE 
AVEC
ROUGE (D). B
RANCHER LE NOUVEQAU CONNECTEUR AU HARNAIS DU MODULE DE HOTTE ENCASTRABLE
. (V
OIR FIGURE
쐏.
)
7. C
ONNECTER LE FIL
DÉNUDÉ ou VERT
SOUS LA VIS
VERTE
DE MISE À LA TERRE
(E
SITUÉE À L
INTÉRIEUR DU MODULE DE HOTTE ENCASTRABLE
. (V
OIR FIGURE
쐏.
)
8. R
ÉINSTALLER LA PETITE PLAQUE RECOUVRANT L
ACCÈS AU HARNAIS ÉLECTRIQUE
.
9. C
HOISIR LA LOCALISATION DU CONTRÔLE MURAL
.
10. P
ASSER LE FIL ÉLECTRIQUE DU MODULE DE HOTTE ENCASTRABLE JUSQU
À LA LOCALISATION DU CONTRÔLE MURAL
11. R
ETIRER LES DEUX VIS RETENANT LA PLAQUE AVANT DU CONTRÔLE MURAL ET DÉTACHER CELLE
-
CI DU CONTRÔLE
. (V
OIR FIGURE
쐄.
)
S
I LE MUR N
EST PAS ENCORE TERMINÉ
12. E
NLEVER LES
PATTES
(F
DES REBORDS DU DESSUS ET DESSOUS DE LA BOÎTE DE JONCTION DU CONTRÔLE
(
INCLUSE
). D
ÉFONCER UNE DES DEUX ENTRÉES DÉFONÇABLES
(G
ET
(H
ET
Y INSTALLER UN SERRE
-
FILS APPROUVÉ
(
NON INCLUS
). (V
OIR FIGURE
쐂.
)
13. P
OSITIONNER LA BOÎTE DE JONCTION DU CONTRÔLE DE FAÇON À CE QUE LES PATTES D
ASSEMBLAGE SOIENT AU MÊME NIVEAU QUE LA FUTURE SURFACE DU MUR
. V
ISSER UN DE SES CÔTÉS
(
GAUCHE OU DROIT
AU MONTANT DU MUR EN UTILISANT
VIS
(
NON INCLUSES
).
14. P
ASSER LE FIL D
ALIMENTATION ÉLECTRIQUE À TRAVERS LE SERRE
-
FILS ET SERRER CELUI
-
CI
S
UITE DES INSTRUCTIONS AU VERSO
.
BEST BY BROAN  P.O. Box 140, Hartford, WI 53027
V05868  rev. B
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Turn off power and lock out service panel before installing,
wiring, or servicing this product. To prevent serious injury from electrical shock or damage to electrical components - DO NOT WIRE HOT! This unit must be grounded.
Never install more than one optional wall control per unit.
HE0025
A
HO0015
HD0094
HE0026
B
E
C
D
!
WARNING
!
When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.
HC0011
F
G
H
F
F
F
HC0008
5 1/2''
3 1/4''
HD0089
W
ALL
STUD
/
MONT
ANT
/
POSTE
MURAL
HC0009
C
B
D
E
CAUTION
When reinstalling the faceplate, ensure that the BARE WIRE (ground) is not contacting other wires.
AVERTISSEMENT
Lorsque vous coupez ou perforez un mur, prenez garde de ne pas endommager les fils électriques ou tous autres appareils cachés.
AVERTISSEMENT
Risque de choc électrique. Le raccordement électrique doit être effectué par du personnel qualifié conformément aux codes et standards. Avant d’installer,
d’effectuer le branchement ou l’entretien de ce produit, coupez l’alimentation électrique au panneau de service et verrouillez-le. Afin d’éviter de graves
blessures causées par un choc électrique, ou des dommages aux composantes électriques - NE PAS BRANCHER EN PRÉSENCE DE COURANT 
ÉLECTRIQUE! Cet appareil doit être mis à la terre.
!
ATTENTION
Ne jamais installer plus d’un contrôle mural optionnel par appareil.
CAUTION
WARNING
!
When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.