Vent-a-Hood PRH18M48SS Instrução De Instalação

Página de 6
Page 5
L157 0311A
Installation Details Continued
14) From inside the hood, using UL listed wire nuts, attach the "neutral" wire to the white lead, the "hot" wire to the black 
lead, and the ground wire to the green lead inside the junction box. Replace the junction box cover.
Warning:  Do not operate hood without  proper ground connection.
15) Raise the blower plate into the hood first aligning the ducting (M600 blower only) and then aligning the blower mounting 
studs to the holes in the blower plate. Secure the blower assembly with the nuts provided. Connect the motor harness 
to the socket next to the power cord on the reverse side of the control housing.
16) To install the baffle filter, hold the filter with the knob facing down and toward the front of the hood.  Insert the back of 
the filter into the back filter channel with enough force to compress the filter spring.  Raise the front of the filter inline 
with the front filter channel and slowly release the spring force.
 
To remove the baffle filter, push the filter knob toward the back filter channel to compress the filter spring.  Lower the 
front of the filter below the front filter channel and slowly release the spring force.
17) Refer to the Owner and Maintenance Guide for proper hood operation. Test all blower and light functions to ensure 
they are operating properly.