PLANNING
GUIDE
www.Dacor.com      Phone: (800) 793-0093  
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
4.20
DCT365
4 ¼" (10.8 cm) min. 
from mounting surface to 
combustibles below
cooktop chassis
E
F
C
D
Minimum distance to combustible side 
wall above countertop (both sides)
F
Vertical
combustible
surface
Rear
wall
5
/
8
" min.
(4.1 cm)
(C) Minimum
(D)
(E)
(F) Minimum
3 ¼” (8.3 cm)
19 
5
/
8
” (49.9 cm)
33 
5
/
8
” (85.4 cm)
7
/
8
” (17.5 cm)
installation Type
(C) Minimum
(D)
(E)
(F) Minimum
DCT365 with no raised vent
3 ¼” (8.3 cm)
19 
5
/
8
” (49.9 cm)
33 
5
/
8
” (85.4 cm)
7
/
8
” (17.5 cm)
DCT365 with DRV36 raised vent
3/8” (1.0 cm)
22 ¾” (57.8 cm)
Stiffener
Cabinet face
Countertop
Floor
3
/
8
” min. (1.0 cm) space 
behind raised vent 
chassis to clear stiffener
3
/
8
” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV36-1 raised vent
Check raised vent 
dimensions/specifications 
to determine proper fit
 DCT365 cooktop
Cutout tolerances: +1/16”, -0,  (+1.6 mm, -0) unless otherwise stated
Cutout Dimensions
sIDE VIEW - DCT365 CookToP WITh ErV36-1 rAIsED VENT
Document # PG04-006
Revised 09/29/10   Page 4/4
36” Wide, Distinctive  
series Gas Cooktop
raised Vent Compatibility
If installing the cooktop with a raised vent, install only 
Dacor raised vent model DRV36. Installation other 
any other model raised vent may cause improper 
operation.