Specifications  
subject to change.
Downdraft Vent
FH30DD50M S    
30" In-Cabinet
30" Downdraft Vent - (FH30DD50MS)
Frigidaire Baseline
Downdraft Vent Specifications
 Voltage Rating – 120V / 60 Hz / 15 Amps
 Connected Load (kW Rating) @ 120 Volts = 0.41 kW (For use on 
adequately wired 120V, dedicated circuit having 2-wire service with a 
separate ground wire. Appliance must be grounded for safe operation.)
 Amps @ 120 Volts = 3.4 Amps
 Do not use same circuit as cooktop.
 Always consult local and national electric codes. Check local building 
codes for installation requirements, as they may vary per locale.
 Locate grounded electrical outlet for 28"- long power cord within 
reachable distance. When installing vent in 30"- wide cabinet, outlet 
cannot be located on back wall of cabinet, but can be wall-mounted 
with access hole in cabinet.
 Downdraft Vent designed for installation with cooktop in island, 
peninsula or conventional installation. (Cutout template provided, 
packed with vent.)
 To ensure proper installation with cooktop, refer to model-specific 
cooktop installation guide on web for dimensions, countertop 
cutout dimensions and cabinet requirements; oversized cabinets 
recommended for ease of installation. Due to varying cooktop depths, 
tight fit is possible between cooktop and vent, depending on overall 
depth of countertop.
 Pre-formed countertops with raised lip and /or backsplash may not 
allow enough flat area for proper installation. Minimum 2-5/16" of flat 
countertop required behind cooktop and 2-1/16" necessary between 
back edge of cooktop and inside of cabinet back. 
 To ensure adequate clearance for air vent when raised /lowered, 1/8" 
gap needed between back edge of cooktop and front of downdraft 
top trim.
 Vent exhaust air outside only.
 Exhaust Duct Required – Galvanized or aluminum duct in 6" round  
or 3-1/4" x 10" rectangular, or combination of both. PVC should  
be used if installing under concrete slab.
 Three blower discharge direction options available; rotate blower 
motor for left, right or down discharge. 
 Consider ductwork location before cutting hole in cabinet. Blower 
motor mounted on slide plate, enabling 3-1/2" left or right adjustment 
to avoid duct interference with joists or other obstructions.
 For maximum efficiency, use shortest and straightest duct run 
possible. System operates most efficiently with up to 60 equivalent 
feet of duct; Downdraft Vent operates properly with ductwork  
up to 100 equivalent feet. (Refer to Calculating Duct Length Table  
in Product Installation Guide.)
 Do not use flexible duct. Round duct instead of rectangular duct 
recommended, especially when elbows are required.
 Thermal breaks such as short section of nonmetallic duct, should  
be used in areas of extreme cold. Cold weather installations should 
have additional backdraft damper installed.
 High level of airflow may affect gas flame on some gas cooktop 
models.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
Accessories information available  
on the web at 
frigidaire.com