Frigidaire FPEH3077RF-SS Ficha De Dados

Página de 4
NOTICE: This service data sheet is intended for use by persons having electrical and mechanical training 
and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade. The 
manufacturer cannot be responsible, nor assume any liability, for injury or damage of any kind arising from 
the use of this data sheet.
IMPORTANT NOTE: This unit includes an EOC (electronic oven control). This board is not field-repairable.  
Verify the unit has the proper oven relay board, oven user interface board, and touch panel based on the 
model number and parts catalog.
Safe Servicing Practices
To avoid the possibility of personal injury and/or property damage, it is important that safe servicing practices 
be observed. The following are some, but not all, examples of safe practices.
1. 
Do not attempt a product repair if you have any doubts as to your ability to complete it in a safe and 
satisfactory manner.
2. 
Before servicing or moving an appliance, remove power cord from electric outlet, trip circuit breaker to 
Off, or remove fuse.
3. 
Never interfere with the proper installation of any safety device.
4. 
Use only replacement parts specified for this appliance. Substitutions may not comply with safety 
standards set for home appliances.
5. 
Grounding: The standard color coding for safety ground wires is green or green with yellow stripes. 
Ground leads are not to be used as current carrying conductors. It is extremely important that the 
service technician reestablish all safety grounds prior to completion of service. Failure to do so will 
create a potential hazard.
IMPORTANT
DO NOT REMOVE THIS BAG
OR DESTROY THE CONTENTS
WIRING DIAGRAMS AND SERVICE
INFORMATION  ENCLOSED
REPLACE CONTENTS IN BAG
p/n A00980615 Rev A (1503)
SERVICE DATA SHEET
ELECTRIC RANGES WITH MODULAR OVEN CONTROLS
CIRCUIT 
ANALYSIS 
MATRIX
Elements
Door Motor
J20-10
Light
J20-6
Conv. Fan
J20-9
Door 
Switch
J5-9
DLB L2 
out K1
Bake
P7
Broil
K2
Conv.
P8
Bake
X
X
X
X
X
Broil
X
X
Conv. Bake
X
X
X
X
X
Conv. Roast
X
X
X
X
X
Clean
X
X
X
Locking
X
Unlocking
X
Light
X
Door Open
X
Door Closed
X
6. 
Prior to returning the product to service, ensure that:
• 
All electric connections are correct and secure.
• 
All electrical leads are properly dressed and secured away from sharp edges, high-temperature 
components, and moving parts.
• 
All uninsulated electrical terminals, connectors, heaters, etc. are adequately spaced away from 
all metal parts and panels.
• 
All safety grounds (both internal and external) are correctly and securely reassembled.
• 
All panels are properly and securely reassembled.
Temperature Adjustment
1. 
Make sure both the oven mode selector and the oven temperature selector are in the OFF position.
Press and hold both the light icon and the clock icon at the same time for a few seconds until the  
display sounds an acceptance chime. AUd should appear in the display.
2. 
Press the + key in the upper part of the display until UPO appears and the default setting of 0° (or the 
last set temperature offset) is showing.
3. 
Using the + or - key in the bottom of the display, press until the desired temperature change (offset) 
is reached. The display will change ± 5° with each key press to a maximum of +35° or a minimum of 
–35°F.  Once the new offset appears in the display, release the key and the control will accept the 
change.
4. 
To return the display to normal, press and hold both the oven light icon and the clock icon at the same 
time until an acceptance chime sounds. The display will return to show the time of day.
Note: Changing calibration affects all baking modes. The adjustments made will not change the broil 
self-cleaning temperature.
Resistance  (ohms)
1000 ± 4.0
1091 ± 5.3
1453 ± 8.9
1654 ± 10.8
1852 ± 13.5
2047 ± 15.8
2237 ± 18.5
2697 ±  24.4
Open  circuit/infinite  resistance
RTD SCALE
Temperature °F (°C)
32 ± 1.9 (0 ± 1.0)
75 ± 2.5 (24 ± 1.3)
250 ± 4.4 (121 ± 2.4)
350 ± 5.4 (177 ± 3.0)
450 ± 6.9 (232 ± 3.8)
550 ± 8.2 (288 ± 4.5)
650 ± 9.6 (343 ± 5.3)
900 ± 13.6 (482 ±7.5)
Probe  circuit  to  case  ground
1
1
1
1
1
1
1
1
1
L1
CONVECTION FAN
J4 TO USER INTERFACE BOARD
LATCH MOTOR
OVEN LIGHT
NEUTRAL
L1
MEAT PROBE
TEMPERATURE PROBE
DOOR SWITCH
MOTOR DOOR LATCH SWITCH
COMMON
PROGRAMMING HEADER
CONVECTION ELEMENT
BAKE ELEMENT
L1 IN
L1 IN
COM L2 OUT
NO:L2 IN
NO:BROIL
COM L1
DLB
BROIL
NEUTRAL
COOLING FAN-LOW
COOLING FAN-HIGH
MEAT PROBE TEMPERATURE VS RESISTANCE TABLE
Temperature
Probe Resistance
77 °F / 25°C
50.020 Kohm +/- 6%
122 °F / 50°C
18.020 Kohm +/- 5%
176 °F / 80°C
6.290 Kohm +/- 5%
212 °F / 100°C
3.400 Kohm +/- 5%
ELECTRONIC OVEN CONTROL (EOC) FAULT CODE DESCRIPTIONS
Fault 
Code
Description of Error Code
Suggested Corrective Action
F01 F02 
F04 F05
Touch panel failure
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
F03
The oven user interface board is incorrectly 
configured.
Replace the control assembly (UIB and touch panel). Make sure you install the latest revision available for this model.
F10
Oven temperature runaway: the cavity tem-
perature has been detected in excess of the 
maximum safe operating temperature.
1. 
If oven is overheating, disconnect power. Check oven temperature probe (RTD) and replace if necessary.
2. 
If the oven temperature probe is good and if oven continues to overheat when power is reapplied, replace the oven relay board.
F11
Stuck key: a key has been detected has 
pressed continuously for 30 seconds or 
more.
1. 
If a key was pressed inadvertently for a long time this error code will be displayed. Make sure there is nothing (water, utensils) in contact with the 
keyboard. The fault code should go away once the key is released and the Stop key is pressed. If the F011 error comes back when a key is pressed it 
means the error condition is still there. If the F011 error does not come back it means the error condition is gone and the oven can be used.
2. 
If the fault code cannot be cleared, test the wiring harness between oven user interface board (connector I2C1 or I2C2) and touch panel (connector 
I2C1 or I2C2).
3. 
If the fault code cannot be cleared and the wiring is good, the touch panel is most likely defective: replace the control assembly (UIB and touch 
panel).
F12
Keyboard configuration alarm: the oven 
user interface board received from the touch 
panel a key code that does not match the 
key map.
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
F13
Data written to non-volatile memory has 
failed verification
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
F15
Keyboard error
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
F16
The oven user interface board cannot read 
the potentiometers.
1. 
Verify that potentiometers are in OFF position correctly, disconnect power to the unit, wait 30 seconds, then reapply power.
2. 
If fault returns, verify harness going to the POTS connector of the user interface board to both potentiometer components.
3. 
If fault persists, replace potentiometers.
4. 
If fault persists, replace the control assembly (UIB and touch panel)
F17
The oven user interface board is unable to 
configure the touch panel.
1. 
Disconnect power to the unit, wait 30 seconds, then reapply power. 
2. 
If fault returns, verify harness going to I2C1 or I2C2 connector of the touch panel.
3. 
If fault persists, replace the control assembly (UIB and touch panel)
F18
Oven relay board failure (wiggler)
Replace the oven relay board.
F19
The oven user interface board is unable to 
configure the oven relay board
1. 
Disconnect power to the unit, wait 30 seconds, then reapply power. 
2. 
If fault returns, verify connection between the oven user interface board (MACS1 or MACS2 connector) and the oven relay board (connector J3 or 
J4).
3. 
If fault persists, replace the control assembly (UIB and touch panel)
4. 
If fault persists, replace the relay board.
F22
Communication failure between the oven 
user interface board and the oven relay 
board
1. 
Disconnect power, wait 30 seconds and reapply power. Check if error condition is still there.
2. 
Test wiring harness between oven user interface board (connector MACS1 or MACS2) and oven relay board (connector J3 or J4).
3. 
If wiring harness is good replace oven relay board.
4. 
If the problem persists replace the control assembly (UIB and touch panel).
F23
Communication failure between the oven 
user interface board and the glass touch 
panel
1. 
Disconnect power, wait 30 seconds and reapply power. Check if error condition is still there.
2. 
Test wiring harness between oven user interface board (connector I2C1 or I2C2) and touch panel (connector I2C1 or I2C2).
3. 
If wiring harness is good replace touch panel.
4. 
If the problem persists replace the control assembly (UIB and touch panel).
F25
F27
The communication between the over user 
interface and the oven relay board cannot 
be initiated.
1. 
Disconnect power to the unit, wait 30 seconds, then reapply power. 
2. 
If fault returns, verify connection between the oven user interface board (MACS1 or MACS2 connector) and the oven relay board (connector J3 or 
J4).
3. 
If fault persists, replace relay board.
4. 
If fault persists, replace the control assembly (UIB and touch panel).
F28
F29
The communication between the over user 
interface and the touch panel cannot be 
initiated.
1. 
Disconnect power to the unit, wait 30 seconds, then reapply power. 
2. 
If fault returns, verify touch panel is connected (verify harness going to I2C1 or I2C2 connector) and is getting power from the oven user interface.
3. 
If fault persists, replace the control assembly (UIB and touch panel).
F30
Open oven temperature sensor (RTD)
1. 
Check probe circuit wiring for possible open or short condition.
2. 
Verify RTD resistance at room temperature (compare to probe resistance chart). If resistance does not match the chart, replace the RTD probe.
3. 
If the problem persists replace the oven relay board.
F31
Shorted oven temperature probe (RTD)
F33
Meat probe temperature sensor shorted or 
too hot
1. 
The error is triggered if the meat probe sees a temperature in excess of 392°F.  Make sure the meat probe was not used in such way that it could 
have seen such temperature. If the tip of the probe is not inserted in the meat it will see the cavity temperature, which can be higher than 392°F 
(depending on the setpoint) and trigger the alarm.
2. 
When the meat probe is connected to the socket inside the oven cavity, if the meat probe is not fully inserted into the socket it may short the contacts 
and cause the error. Make sure the probe is inserted as much as it can.
3. 
Verify meat probe resistance at room temperature. Compare to meat probe resistance chart. If the meat probe does not match the chart, replace it.
4. 
If the above steps failed to correct the problem, replace the oven relay board.
F50
A/D Out of Range: the oven relay board is 
unable to read the status of the switches 
(door, MDL)
Replace the oven relay board.
F90
Motor Door Lock mechanism failure. The 
oven control does not see the Motor Door 
Lock running.
1. 
Disconnect power to the unit, wait 30 seconds, then reapply power. Try again to make the door lock or unlock (ex: initiate a Lockout or a Clean cycle). 
2. 
Check if the Lock Motor is running or not. If it is not running, test the wiring between the Lock Motor and the oven relay board. If the wiring is good, 
check if there is 120VAC at the motor when it is expected to run  to see if the failure originates from a bad motor (120VAC present but not turning) or 
a problem with the relay board (J20 pin 10 on the oven relay board  is the output to the Lock Motor). The Lock Motor can also be tested by applying 
120VAC directly to the motor (unplug it from the relay board first). If the Lock Motor does not run when 120VAC is applied replace the Lock Motor 
Assembly. If it is the relay board that does not provide 120VAC to the Lock Motor replace the oven relay board.
3. 
If the Lock Motor is running but the oven control cannot find the locked or unlocked position (ex: motor turns continuously until F90 fault code is 
generated) the Lock Switch needs to be verified. Check wiring between Lock Switch and oven relay board. Verify with ohmmeter if the switch makes 
contact properly (verify continuity with ohmmeter when the switch is pressed). If the Lock Switch is defective replace the Motor Lock Assembly.
4. 
If all above steps failed to correct the situation, replace the oven relay board.
F95
Motor Door Lock mechanism failure. The Mo-
tor Door Lock does not stop running or the 
Lock Switch sends an invalid signal.
1. 
The problem can be caused by a faulty Lock Switch or by a defective oven relay board.  If the Motor Door Lock is always running (as if the relay 
controlling it is stuck closed) replace the oven relay board.
2. 
If the motor is not always running replace the Motor Lock Assembly.
F96
The oven door has been detected open 
during a Self Clean cycle.
1. 
This error occurs if the door switch has lost its contact during a Self Clean cycle. Make sure the oven door closes well and fully presses on the door 
switch plunger when the door is locked, and no one attempted to pull on the oven door during the Self Clean cycle.
2. 
Test continuity of wiring between the door switch and the oven relay board, make sure the door switch is well connected. With an ohmmeter, verify the 
switch is closed when the plunger is pressed. If the door switch is found to be defective replace the door switch.
3. 
If the switch and wiring are good and the problem persists, replace the oven relay board.
F97
MDL invalid state. Relay board (OVC) 
sensed the motor door lock in a state it 
should not be in according to the user 
interface board.
1. 
Disconnect power to the unit, wait 30 seconds, then reapply power.
2. 
If fault persists, replace motor door lock.
3. 
If fault persists, replace the oven relay board.