Whirlpool UXT4036ADW Instrução De Instalação

Página de 24
4
Product Dimensions
Installation Clearances
Venting Requirements
These range hoods are factory set for non-vented (recirculating) 
installations and come with a charcoal filter. See the “Assistance 
or Service” section for information on ordering a charcoal filter 
kit, Part Number W10355450.
Electrical Requirements
Observe all governing codes and ordinances. 
Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 (latest 
edition), or CSA Standards C22.1-94, Canadian Electrical Code, 
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes 
and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 
required.
If the house has aluminum wiring, follow the procedure 
below:
1. Connect a section of solid copper wire to the pigtail 
leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of 
the appliance as specified on the model/serial rating plate. 
The model/serial plate is located behind the filter on the rear 
wall of the range hood.
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
A. 18” (45.7 cm) minimum distance from electric cooking surface.
24" (61.0 cm) minimum distance from gas cooking surface.
30" (76.2 cm) suggested maximum above the cooking surface.
B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop.
C. 30" (76.2 cm) minimum cabinet opening width for  30" (76.2 cm) 
models and 36" (91.4 cm) minimum cabinet width for 36" 
(91.4 cm) models.
D. 12" (30.5 cm) cabinet depth.
E. 36" (91.4 cm) base cabinet height.
1" 
(2,5 cm)
4
¹⁵⁄₁₆
(12,5 cm)
6
⁹⁄₁₆
" (16,7 cm) ou
9
⁹⁄₁₆
" (24,4 cm)
 
29
¹⁵⁄₁₆
" (76,0 cm)
 
ou 
35
¹⁵⁄₁₆
" (91,0 cm)
18
⁵⁄₈
(47,3 cm)
 1¹⁄₂
(3,8 cm)
9" 
(22,9 cm)
2" 
(5,1 cm)
1" 
(2,5 cm)
B
A
C
D
E