INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools needed
Level
Drill with 1¼" (3.0 cm), 
³⁄₁₆" (4.8 mm), ¹⁄₈" (3.0 mm), and 
⁵⁄₁₆" (7.9 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Metric hex key set
Parts needed
Home power supply cable
½" (12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
1 wall or roof cap
Metal vent system
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs 
installed
3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector
2 metal grease filters for 30" (76.2 cm) model
3 metal grease filters for 36" (91.4 cm) model
T20 Torx
®† 
 adapter
4 - 5 x 45 mm mounting screws
6 - 4.5 x 13 mm screws
3 - 4 x 8 mm screws
4 - 10 x 50 wall anchors
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located behind the left filter on the rear wall of the vent 
hood.
Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
The canopy hood is factory set for venting through the roof or 
wall. 
All openings in ceiling and wall where canopy hood will be 
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.
Product Dimensions
Front View
†®TORX is a registered trademark of Saturn Fasteners, Inc.
12"
(30.5 cm)
3
¹⁄₈
(7.9 cm)
30" (76.2 cm)
36" (91.4 cm)
23" (58.4 cm)
10" 
(25.4 cm)
³⁄₈
"
(1.0 cm)
2
⁹⁄₁₆
(6.5 cm)
7½"
(19.0 cm)
29
¹⁄₈
" (74.0 cm): 30" (76.2 cm) models 
35
¹⁄₈
" (89.2 cm): 36" (91.4 cm) models