Frigidaire FHWC3025MS Manual Do Proprietário

Página de 17
11
Use ¹⁄
8
” (3 mm) drill bit and drill 4 pilot holes as shown. 
NOTE: Make the drill holes on the thin area of the slot.  
 
 
 
Install the 4 - .45 cm x 1.3 cm mounting screws in 
  pilot holes. Leave about ¼” (6.4 mm) space between   
  screw heads and cabinet to slide range hood into place. 
 
 
 
For roof installations, remove the top rectangular 
  vent knockout. For wall installations, remove the rear    
  rectangular vent knockout. 
 
 
 
 
 
 
 
 
 
Install the 3¼” x 10” (8.3 x 25.4 cm) vent connector. 
 Attach to range hood with the .35 x .95 cm screws 
  that you previously removed (step 1)  and remove tape  
 from damper flap.
  
NOTE
The 3¼” x 10” (8.3 x 25.4 cm) rectangular vent 
connector can be installed up to 1” (. cm) on 
either side of the hood center to accommodate 
off center ductwork.
If a vent damper is installed with a wall cap with  
  damper, check that they do not interfere with each 
 other. Remove the vent connector damper flap if 
  they interfere. 
.
4.
.
¹⁄4”
(6.4 mm)
A
A. Drill pilot hole
A
B
A. Vertical connector
B. 3.5 x 9.5 mm screws
C. Vent knockouts
D. Horizontal connector
Power Supply Cable Installation
For direct wire installations, run the home power 
  supply cable according to the National Electric Code 
  or CSA standards and local codes and ordinances. 
  There must be enough wiring from the fused disconnect  
 (or circuit breaker) box to make the connection in the 
 hood electrical terminal box.  
 
  
NOTE
Do not reconnect power until the installation is 
complete.
 
Remove the screw from the  
 terminal box cover.  
 Remove terminal box cover  
  and set aside. 
 
 
 
Remove the power supply knockout from the top 
  or rear of the vent hood (depending on the incoming 
  location of your home power supply cable) and  
  install a UL listed or CSA approved ½” strain relief. 
 
 
 
 
 
 
 
 
 
Using 2 or more people, lift the hood into final position. 
  Feed enough electrical wire through the ½” UL listed  
  or CSA approved strain relief to make connections in  
 the terminal box. Tighten the strain relief screws.
Position the range hood so that the large end of 
  the keyhole slots are over the mounting screws. 
  Then push the hood toward the wall so that the screws  
  are in the neck of the slots. Tighten the mounting screws,  
  making sure the screws are in the narrow neck of slots.
Connect ventwork to hood. Seal joints with vent  
  clamps or duct tape to make secure and airtight.
Check that back draft dampers work properly.
1.
.
.
4.
.
.
.
A
B
A. Terminal box cover
B. Screw
A
A. Power supply  
     knockout
INSTALLING THE HOOD