Wine Guardian 1 Ton Water Cooled 8,000 BTU Wine Cooling Unit Ficha De Características

Página de 1
TM
Wine Guardian Specifications
•1. Net cooling capacity @ cellar temp & humidity of 55 Deg F & 60 % RH / 60 Deg F & 60% RH and at rated 
airflow.Reduce capacity by 3% for each 10% reduction in either condenser or evaporator airflow, 5% for both.
2. Air Innovations reserves the right to make changes to this document without prior notice at its sole discretion.
3. All ratings @ sea level.
Model Number 
24S025 
24S050 
24S088 
24S200 
 
 
 
 
 
Performance 
 
Nominal Tonnage 
Ton 
1/4 
1/2 
Nominal Compressor 
HP 
1/3 
1/2 
2.5 
Net Cooling Capacity* 
       @ 70 Deg F Ambient
 
BTUH  3300 / 3650
5600 / 6050 
8400 / 9100 
16200 / 17750
       @ 80 Deg F Ambient 
BTUH  3000 / 3300
5300 / 5700 
7800 / 8450 
15200 / 16550
       @ 90 Deg F Ambient 
BTUH  2800 / 3050
4850 / 5275 
7300 / 7900 
14100 / 15350
Controls 
 
Type 
Room mounted non-programmable thermostat 
Accuracy ± 
2°F 
Evaporator Section 
 
Fan Motor Size 
Watts  
75 
100 
195 
240 
Rated Air Flow 
CFM 
235 
430 
510 
740 
Air Flow with 25' flex duct 
CFM 
207 
400 
485 
715 
Air-cooled Condenser Section 
 
Fan Size  
Watts 
75 
100 
195 
240 
Rated Air Flow  
CFM 
253 
400 
500 
750 
Air Flow with 25' flex duct 
CFM 
220 
365 
475 
720 
Water-cooled condenser Section (option) 
 
Water usage at 40 Deg F rise 
GPM 
0.30 
0.60 
1.20 
2.50 
Pressure drop 
PSI 
0.40 
0.40 
0.85 
1.20 
Pipe connection size (in/out) 
Inches 
0.50 
0.50 
0.50 
0.50 
Heat 
 
Type 
Integral electric heater coil 
 
Capacity 
Watt/btuh
1000/3413 1000/3413  2000/6826  2000/6826 
Temperature rise - including fan 
Deg F 
13.5 
8.6 
12.0 
8.1 
Humidifier 
 
Type 
Removable Drip pad with integral fan 
Supply water temp of 60 Deg F 
gal./day
1.6 
Supply water temp of 90 Deg F 
gal./day
3.5 
Supply water temp of 120 Deg F 
gal./day
5.1 
Control 
 
Cellar mounted digital humidistat 
Electrical Requirements 
 
 
Power Requirements 
V/P/H 
115/1/60 
115/1/60 
230/1/60 
230/1/60 
Current Draw - Cooling mode  
Amps 
8.6 
11.9 
9.0 
16 
Current Draw - Heating mode 
Amps 
9.4 
9.6 
9.6 
10 
Minimum Circuit Size 
Amps 
15 
15 
15 
20 
Optional Low Ambient  
Amps 
0.4 
0.4 
0.2 
0.2 
Optional Humidifier 
Amps 
0.3 
0.3 
0.2 
0.2 
Typical Testing Data (Factory) 
 
Head Pressure 
psig 
159 
140 
140 
138 
Suction Pressure 
psig 
40 
30 
25 
27 
Condenser Inlet temperature 
Deg F 
81 
74 
79 
78 
Condenser Outlet temperature 
Deg F 
98 
98 
99 
107 
Evaporator Inlet temperature 
Deg F 
56 
55 
57 
55 
Evaporator Outlet temperature 
Deg F 
44 
44 
43 
46 
Agency Approval(s) 
ETL - Conforms to UL Std. 1995, Can/CSA C22.2 No 236