Le Cache Loft 1400 172-Bottle Wine Cabinet - Black Matte Manual Do Proprietário

Página de 31
L E   C A C H E   P R E M I U M   W I N E   C A B I N E T S 
 
 
 
-23- 
 
Protection Mechanisms 
 
Protection 
Mechanisms 
To protect the components in the cooling unit as well as 
the wine inside the cellar, the cooling unit is programmed 
to shut down certain components under certain 
circumstances, as follows: 
 
Scenario 
What it means What 
happens 
P2 > 70°F for more 
than 1 hour 
The evaporator probe 
is measuring 
temperatures that are 
too warm  
 
The evaporator fan will turn off 
until the evaporator temperature 
falls below 70°F 
P3 > 125°F for more 
than 2 hours 
The condenser probe 
is measuring 
temperatures that are 
too hot  
The compressor and condenser 
fan will turn off until the 
condenser temperature falls 
below 120°F 
 
 
 
Optional Protection 
Mechanisms 
CellarPro cooling systems can be programmed to turn off 
the compressor and condenser fan in the event of an HA2 
alarm, as described below.  If you’d like to turn on this 
protection mechanism, please call us toll-free at 
877.726.8496 
 
P3 > 125°F for more 
than 2 hours 
The condenser probe 
is measuring 
temperatures that are 
too hot  
The compressor and condenser 
fan will turn off until the condenser 
temperature falls below 120°F