20) Mix a new batch of the sanitizing solution and slowly pour it into the water tank.
21) Move the control switch to the “WASH" position.
22) After circulating the sanitizing solution for about 15 minutes, move the control switch to
the “OFF" position.
23) Disconnect the suction tube by compressing
both plastic tabs to unlock the joint in the
direction of the black arrows and pulling the
tube clear.
24) Spread out the tabs on both sides of the water
tank to unlock it, then pull it out toward you.
Drain the tank.
25) After draining, slide in the water tank along
the rails at the bottom of the right and left
brackets until it clicks into place.
26) Refit the suction tube onto the water tank inlet
by pushing the joint to lock it securely in the
direction of the arrows. A loose fitting may
cause a water leak.
27) Repeat 20) through 26) one time.
28) Open the water supply line shut-off valve.
Water Tank
Joint
       Drain
Suction Tube
Unlock
       Unlock
Lock
                  Lock
Bracket
Rail
          Rail