Marvel Sentry Digital Drawer Refrigerator - White/Custom Overlay Door Guia De Iniciação

Página de 20
Sentry System™ “
Troubleshooting” Function “
Quick
” R
eference
Note: 
All keypad presses are confirmed with an audible tone when released.
Function
Function Access
Control Confirmation / Comment
Show Room Mode
Enable the showroom mode by pressing and holding the “
ON/OFF
” key 
while performing a “P
ower On Reset
” (POR). i.e. disconnect and reconnect 
the power supply to the unit. Exit Showroom Mode by initiating a POR only
.
Show Room Mode will disable the refrigeration system and fans while allow
-
ing the internal lights, display
, and user interface panel to function. Lights will 
time
-out after 15 minutes of continuous on-time while in Show Room Mode 
as a safety feature. The 15 minute light on time can be reactivated by closing 
and opening the door or by pressing the “LIGHT” key
.
Error Codes
E1
Compressor fault, (high/low amps)
E2
Condenser fan motor fault, (high/low amps)
E3
Evaporator thermistor “sensor B
” fault, (out of range)
E4
Display thermistor “sensor A
” fault, (out of range)
Please call a qualified service technician if any of these codes are displayed.
Service Diagnostics
To enter and exit Service Diagnostics Mode, press and hold the “
W
ARMER
” 
key while pressing the “COLDER
” key four (4) times in five (5) seconds. 
Service Diagnostics Mode will automatically exit after five (5) minutes of no 
keypad entry
.
Display Error Code Reference:
The microprocessor in the control continually monitors critical refrigeration 
system components for proper operation. If component parameters exceed 
normal operation specifications, the display will automatically flash the 
respective error code as follows:
  
Service Diagnostics Mode enables service technicians to identify the firmware 
and software versions, test status of “model specific” system components and 
sensors, and change state of components where applicable, (i.e. -
compressor 
“ON/OFF
” etc.). While in Service Diagnostics Mode, tests are incremented by 
pressing the “SET” key and specific component state can be changed to “on
” 
or “off
” by pressing the “
W
ARMER
” or “COLDER
” keys respectively
. The fol
-
lowing component tests are available:
                                                                        Available Status Indicators
Test #
Component Description
OK
Off/
Open
On/
Short
-
ed
0
Temperature Sensor
, Upper
0-
00
01
1
Temperature Sensor
, L
ower
1-
10
11
2
Compressor
n/a
20
21
3
Interior / Ice Maker F
an
n/a
30
31
4
Reverse Gas Solenoid
n/a
40
41
5
Condenser F
an
n/a
50
51
6
Mullion Heater
n/a
60
61
7
Door A Sense
n/a
70
71
8
Door B Sense
n/a
80
81
9
Door C Sense
n/a
90
91
NO
TE
: The Door Sense is located between the Upper Compartment Display 
and the “
ON/OFF
” key and can be tested with any magnet.
Door sense “C
” (T
est #9) is in the menu but not available on drawer units.
15