Before installing the hood
For the most effcient air flow exhaust, use a    
 
straight run or as few elbows as possible.
         Vent unit to outside of building and recirculating.
At least two people are necessary for installation. 
 
The hood is fitted with Screws and Drywall  
 
 
Anchors suitable for most surfaces, consult a    
 
Qualified Installer, check if they perfectly fit with  
 
your cabinet/wall.     
 
 
 
Do not use flex ducting. 
 
 
 
COLD WEATHER installations should have an    
 
additional backdraft damper that is already     
 
installed to minimize backward cold air flow and a 
 
 nonmetallic thermal break to minimize  
 
 
conduction of outside temperatures as part  
 
 
of the  ductwork. The damper should be  
 
 
on the cold air side of the thermal break. 
 
 
The break should be as close as possible  
 
 
to where the ducting enters the heated portion   
 
of the house. 
 
 
 
 
 
Make up air: Local building codes may require the  
 
use of Make-Up Air Systems when using Ducted 
 
Ventilation Systems greater than specified CFM of  
 
air movement. 
 
 
 
 
 
The specified CFM varies from locale to locale.  
 
Consult your HVAC professional for specific    
 
requirements in your area.
1.
2.
3.
4.
5.
6.
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a quali!ed electrical installer.
To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 — latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code, Part 1 and
C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it
is recommended that a quali!ed electrician determine
that the ground path is adequate.
Do not ground to a gas pipe.
Check with a quali!ed electrician if you are not sure
range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspector’s
use.
The range hood must be connected with copper wire
only.
The range hood should be connected directly to the
fused disconnect (Or circuit breaker) box through
metal electrical conduit.
Wire sizes must conform to the requirements of the
National Electrical Code ANSI/NFPA 70 — lat-
est edition*,or CSA Standards C22.1-94, Canadian 
Electrical Code Part 1 and C22.2 No. 0-M91 - latest 
edition**and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park 
Quincy,Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 
44131-5575
Important safety Instructions - Electrical & Installation
requirements
READ AND SAVE THESE INSTRUCTIONS
Electrical & Installation requirements