Appendix A.  Changing COM220 Settings 
12:  Initiate Telecommunications (P97) 
 1:  22 
 Phone 
Modem/9600 
Baud 
 
;set baud-rate/modem 
  2:  5 
  Disabled when User Flag 5 is High 
  3:  45 
  Seconds Call Time Limit  
 
  4:  0 
  Seconds Before Fast Retry 
 5:  0 
 Fast 
Retries 
  6:  0 
  Minutes Before Slow Retry 
  7:  3 
  Failures Loc [ Failures  ] 
 8:  222 
 Callback 
ID 
;must also enter callback ID in LoggerNet Setup 
 
13:  Extended Parameters (P63) 
;7-digit phone number 
 1:  5 
 Option 
 2:  5 
 Option 
 3:  5 
 Option 
 4:  1 
 Option 
 5:  2 
 Option 
 6:  1 
 Option 
 7:  2 
 Option 
  8:  13 
  Option       ;13 is the termination character; always place after phone number 
 
 
End Program 
 
A.4.4  Example Programs for Data-Callbacks via a CR1000 
Datalogger Router.  
In order to do data callbacks via a datalogger router with COM220 and RF401s 
or MD485s, they must all be configured to communicate with one another.  In 
addition, two programs are necessary: one for the datalogger router and one for 
the remote datalogger.  Below are example programs for a datalogger router 
and a remote datalogger.  For these examples, the COM220 is configured for 
SDC7 and the router datalogger has the following settings (you can enter 
these settings via the datalogger keypad or from the LoggerNet status table):  
PakBusAddress = 2, IsRouter = 1 or True, and BeaconSDC8=30, enabling the 
router to discover the remote.  The remote datalogger’s PakBusAddress = 1.  
In addition, the RF401s or MD485s are set for CSDC8 (see the RF401 or 
MD485 manual for directions on configuring these devices).  
Program for CR1000 Router: 
'Router program for data callback via router w/ phone link to LoggerNet 
'Phone to MD485 or RF401 w/DL at Base 
'Router PakBus Address = 2, IsRouter = 1, BeaconSDC8 = 30 to discover Remote DL which has 
PBA = 1 
'Router COM220= SDC7; Base RF401 CSDC8; Remote RF401 CSDC8. 
'LoggerNet PakBusPort has PBA = 4094 
 
‘  PC-pcMODEM --------COM220sdc7-CR1000(2)-RF401sdc8~~~~~~~~~~~RF401sdc8-CR1000(1) 
 
Public PanelTemperature, BatteryVoltage, DialSuccess 
Public Flag(10) AS BOOLEAN 
 
A-11