Mitsubishi Electronics Q172HCPU Manual Do Utilizador

Página de 454
 
 
 
5 - 1 
5   SERVO PROGRAMS FOR POSITIONING CONTROL 
 
5. SERVO PROGRAMS FOR POSITIONING CONTROL 
Servo programs specify the type of the positioning data required to execute the 
positioning control in the Multiple CPU system. 
This chapter describes the configuration and setting method of the servo programs. 
Refer to Chapter "6 POSITIONING CONTROL" for details of the servo program. 
 
5.1 Servo Program Composition Area 
This section is described the composition of servo programs and the area in which 
stores the servo program. 
 
5.1.1 Servo program composition 
A servo program is composed a program No., servo instructions and positioning data. 
When a program No. and the required servo instructions are specified using a 
peripheral device, the positioning data required to execute the specified servo 
instructions can be set. 
 
 
[Explanation of the program]
K11 . . . . . . . Program No.11
ABS-3 . . . . . 3 axes linear interpolation control as absolute
                     data method.
Axis1,  3000000.0
Axis2,  5500000.0    
  . . .
Axis used and positioning address
Axis3, -2500000.0
 
 
 
 
Used axes
 
Positioning address
 
3000000.0[µm] 
5500000.0[µm] 
-2500000.0[µm] 
 
Program No.
Servo instruction
Positioning
data
<K   11>
ABS-3
 Axis           1,
 Axis           2,
 Axis           3,
 Combined speed
 Dwell
 M-code
 P.B.
3000000.0
5500000.0
-2500000.0
40000.00
2500
12
3
Control units
[mm]
[mm]
[mm]
[mm/min]
[ms]
Number of program steps              10
Number of used programs  20/13312
 
 • Combined speed ……… Command speed for the 3 axes 
                                             (axis 1, axis 2, axis 3) combination
                                                                   40000.00 [mm/min] 
 • Dwell ……………………. Dwell time             2500 [ms] 
 • M-code …………………. M-code                      12 
 • P.B. ……………………... Parameter block No.   3 
 
 
 
Fig. 5.1 Composition example of servo program 
 
(1)   Program No. ........... This No. is specified using the Motion SFC program. 
Any No. in the range of 0 to 4095 can be set. 
 
(2)   Servo instruction .… Type of positioning control is indicated. 
Refer to Section 5.2 for details. 
 
 
 
 
 
 
 
 
 
 
 