Furuno 1724C Manual Do Utilizador

Página de 247
6. DATA TRANSFER 
 
 
6-8
6.4  Receiving Data Via Network Equipment 
1.  You can receive waypoints, routes, marks and lines from NavNet equipment. 
 
2. Press the MENU key. 
3.  Press the SYSTEM CONFIGURATION soft key. 
4.  Press the DATA TRANSFER soft key. 
5.  Press the RECEIVE DATA VIA NETWORK soft key. 
HOST NAME
 PLOT - - - - 
MARKS & LINES
OFF
WAYPOINTS & ROUTES
OFF
RECEIVE
      DATA
EDIT
RCV
RETURN
 
Receive data menu 
6.  Select HOST NAME, then press the EDIT soft key. 
HOST NAME
¤
1 (NAVNET1)
¡
2 (NAVNET2)
¡
3 (NAVNET3)
¡
4 (NAVNET4)
 
Host name window 
7. Use the cursor pad to choose host name from which to receive data, then push the 
ENTER knob. 
8.  Select the data you wish to receive, then press the EDIT soft key. For example, select 
MARKS & LINES. 
MARKS & LINES
¡
¤
ON
OFF
 
Marks & lines window 
9.  Select ON or OFF as appropriate, then press the ENTER soft key. 
10. Turn WAYPOINTS & ROUTES on or off as appropriate. 
11. Press the RCV soft key followed by the ENTER knob. The message “NOW RECEIVING 
DATA.” is displayed. If no data could be found, the message “(HOST NAME)’ IS NOT 
FOUND.” appears. When the transfer is completed, the message “DATA TRANSFER 
COMPLETED. PUSH ENTER KNOB TO CONTINUE.” appears. Push the ENTER knob 
to finish. 
12. Press  the  MENU key to close the menu.