Mitsubishi Electronics MDS-B Manual Do Utilizador

Página de 188
VI 
(3) Trial operation and adjustment 
 
CAUTION 
 
Check and adjust each parameter before starting operation. Failure to do so could lead to 
unforeseen operation of the machine. 
 
Do not make remarkable adjustments and changes as the operation could become unstable. 
 
(4) Usage methods 
 
CAUTION 
 
Install an external emergency stop circuit so that the operation can be stopped and power 
shut OFF immediately. 
 
Unqualified persons must not disassemble or repair the unit. 
 
If the alarm is reset (RST) with the operation start signal (ST) ON, the servomotor will restart 
suddenly. Confirm that the operation signal is OFF before resetting. Failure to observe this 
could lead to accidents. 
 
Never make modifications. 
 
Reduce magnetic interference by installing a noise filter. The electronic devices used near the 
servo amplifier could be affected by magnetic noise. 
 
Always use the linear servomotor and servo amplifier with the designated combination. 
 
The linear servomotor basically does not have any devices such as the magnetic brakes 
installed. Thus, when using this for an axis onto which an unbalance force is applied, such as 
a gravity axis, install a stopping device on the machine side to secure safety. 
 
Always carry out trial operation after changing the program or parameters, and after 
maintenance and inspection. 
 
Do not enter the machine's movable range during automatic operation. 
 
For an unbalanced axis, such as a gravity axis, basically balance it with a device such as a 
counterbalance. With the linear motor, the continuous thrust is lower than the rotary motor, so 
if the axis is unbalanced the motor's heating amount will increase. If an error should occur, 
the axis will drop naturally. This is hazardous as the dropping distance and dropping speed 
are large. 
 
(5) Troubleshooting 
 
CAUTION 
 
If a hazardous situation is predicted during stop or product trouble, install an external brake 
mechanism. 
 
If an alarm occurs, remove the cause and secure the safety before resetting the alarm. 
 
Never go near the machine after restoring the power after a failure, as the machine could start 
suddenly. (Design the machine so that personal safety can be ensured even if the machine 
starts  
suddenly.)