Furuno Ls4100 Manual Do Utilizador

Página de 48
 
 
36
4.9 Installation 
Menu 
The installation menu mainly contains 
items which are set at installation. 
 
1.  Turn on the power while pressing the 
[MENU/ESC] key. Continue pressing 
the [MENU/ESC] key until the 
Installation menu appears. 
SIMULATION
On
TEST ...
LCD PATTERN ...
MEMORY CLEAR 
NMEA PORT
: In/Out
NMEA MIX
: Off
GPS WAAS*
: Off
SET BOTTOM LEVEL ..
Installation Menu
* = Setting cannot be changed when
NMEA PORT setting is "IN/IN."
 
Installation menu 
SIMULATION:
 The simulation mode 
provides, without connection of the 
transducer, simulated operation of the 
equipment, using internally generated 
echoes. All controls are operative. The 
message “SIM” appears at the top right 
corner on the screen when the 
simulation mode is active. 
 
1.  At the installation menu, press ► to 
open the simulation mode options 
window. 
2. Press ▼ to choose “On” to turn on 
the simulation mode. 
3.  Press the [POWER/BRILL] key 
about three seconds to turn off the 
power. 
4.  Press the [POWER/BRILL] key to 
turn on the power. “SIM” appears at 
the top right corner of the display. 
5.  To turn off the simulation mode, 
select Off at step 2. 
 
NMEA port setup 
(NMEA PORT, NMEA MIX) 
The POWER port can function as an 
input port or input/output port. Change 
the setting to “In/In” when connecting 
GP-310B/320B and a wind sensor. 
 
When connecting the GP-310B/320B 
and a wind sensor, first turn on “GPS 
WAAS” (in the Installation menu) and 
then select “In/In” as the NMEA port 
setting. 
 
1.  Turn on the power while pressing 
and holding down the [MENU/ESC] 
key. Continue pressing the 
[MENU/ESC] key until the 
Installation menu appears. 
2.  Choose NMEA PORT, and then 
press ► to display the NMEA port 
options window. 
3. Use ▲ or ▼ to choose In/Out or 
In/In as appropriate. 
In/Out:
 Input and Output (default 
setting) 
In/In:
 Input only (Available with 
connection of the GP-310B/320B 
and a wind sensor.) 
4. Press ◄, choose NMEA MIX, and 
then press ► to display the NMEA 
MIX options window. 
5. Use ▲ or ▼ to choose Off or On. 
Choose On to output input data. 
Off:
 Outputs the data sentences of 
LS-4100 only. 
On:
 Outputs the data sentences of 
LS-4100 and sentences which are 
input from other equipment. 
6.  To restore normal operation, turn off 
the power and then turn it on again.